| General |
| Cable type | Patch cable |
| Category | Cat7 |
| Frequency bandwidth | 600 MHz |
| Insulation | halogen-free (LSZH) |
| Colour | Grey |
| Number of conductors | 4 pairs |
| Number of poles | 8 |
| Outer diameter | 6,2 mm |
| Conductor cross section | AWG26 |
| Construction | CU-braided with twin wire |
The VOKA Patch Cable Cat7, type LAN600STPC GR flexFRNC4PR AWG, is a flexible, halogen-free data cable for use in network infrastructures with high requirements for bandwidth and signal integrity. It is designed for frequencies up to 600 MHz and is suitable for use in modern Ethernet networks, particularly in environments where high data rates and low interference are required. The cable features S-STP (S/FTP) shielding, where each pair of conductors is shielded with foil and additionally the entire cable is shielded with a braid, ensuring effective protection against electromagnetic interference. The construction with 8 conductors and an outer Ø of 6.2 mm allows for compact installation without compromising mechanical robustness.
Applications
This cable is intended for use in structured cabling systems in the field of IT and telecommunications infrastructure. It is suitable for use in offices, server rooms, data centres, as well as industrial environments where high data integrity and interference protection are required. The halogen-free construction (LSZH) makes it particularly suitable for rooms with high safety requirements, as no toxic fumes are released in case of fire. The flexibility of the cable facilitates installation in confined spaces and under frequent bending stress.
Functions and Features in Detail
The cable consists of 4 pairs of conductors, each shielded with foil and a copper braid overall shielding. This S-STP structure ensures high shielding effectiveness and minimizes the impact of electromagnetic interference (EMI). The conductors are made of AWG26 (equivalent to a diameter of approximately 0.4 mm), providing sufficient conductivity while maintaining flexibility. The twin-conductor construction (copper braid with twin-conductor) supports mechanical stability and signal transmission. The cable is grey in colour, which ensures good visibility in cabling systems.
Technology Explained Simply
The S-STP (Screened Shielded Twisted Pair) shielding technology means that each individual pair of conductors is shielded with a metallic foil, and additionally the entire cable is surrounded by a metallic braid. This double shielding reduces electromagnetic interference from external sources and simultaneously prevents signal radiation outward, which is particularly important at high frequencies. The frequency bandwidth of 600 MHz enables use in networks capable of transmitting up to 10 Gbit/s, such as 10GBASE-T. The halogen-free insulation (LSZH) ensures that no toxic gases are released in case of fire, increasing safety in enclosed spaces.
Compatibility and Accessories
The cable is compatible with network devices supporting Cat7 or higher standards. It can be connected with RJ45 connectors, and the use of field-terminable connectors (e.g. CAT6A or CAT8) is possible, provided mechanical and electrical requirements are met. Suitable accessories include tools such as TP crimping pliers, wire strippers, cable ties, and Velcro tape, which support installation and cable management. The use of tools for field-terminable installation enables quick and reliable connections without requiring special tools or additional components.
Installation and Mounting
Installation is carried out by connecting with RJ45 connectors, and the use of tools such as crimping pliers and wire strippers is recommended. The cable's flexibility facilitates installation, especially in narrow or hard-to-reach areas. The use of cable ties or Velcro tape ensures orderly routing and prevents tangling. Cabling should be carried out in accordance with applicable standards and regulations for structured cabling systems to ensure optimal performance and longevity.
Operational Advantages
The cable offers high signal quality due to double shielding and high bandwidth, resulting in stable and fast data transmission. The halogen-free construction increases safety in enclosed spaces. The flexibility and compact diameter simplify installation and maintenance. The use in combination with field-terminable connectors enables quick and flexible adaptation to different network environments.