Further information for VDE-Kabel TC75900-100HSSP Cat6 S-STP Installation Cable 100m
General
Shielding type
S-STP(S/FTP)
Category
Cat6
Bandwidth
250 MHz
Number of conductors
8
Conductor cross-section
0,6 mm
Conductor
Rigid
AWG standard
23/1
Outer diameter
7,3 mm
Material
Copper
Halogen free
The VDE-Kabel TC75900-100HSSP is a Cat6 installation cable designed for use in structured cabling systems. It features S-STP(S/FTP) shielding, where each pair of conductors is individually shielded with foil and additionally protected by an overall braid shield. This construction ensures high resistance to interference and minimizes electromagnetic influence, which is particularly advantageous in environments with high electromagnetic noise. The cable is designed for a bandwidth of 250 MHz, enabling high-speed data transmission and meeting the requirements of modern networks. It is halogen-free, meaning lower toxicity and smoke development in case of fire, making it suitable for indoor use.
Applications
This cable is designed for use in structured cabling systems in offices, server rooms, industrial facilities, and other installations where reliable and high-quality data transmission is required. Its installation properties make it particularly suitable for routing in cable ducts, wall installations, or underfloor. Due to its shielding and high bandwidth, it is also suitable for applications with high data rates, such as Gigabit-Ethernet.
Functions and Features in Detail
The cable consists of eight individual copper conductors with a diameter of 0.6 mm, manufactured as rigid inner conductors. The conductors are produced according to the AWG23/1 standard, ensuring a stable and conductive connection. The overall braid shielding combined with individual foil shielding of each conductor pair provides effective protection against electromagnetic interference. The outer diameter is 7.3 mm, enabling a compact design without compromising mechanical stability. The halogen-free construction reduces fire hazard and toxicity in case of fire, increasing safety during operation.
Technology Explained Simply
The designation S-STP(S/FTP) describes the shielding type: each conductor pair is shielded with foil (F/), and the entire cable is additionally wrapped in a braid (S/). This dual shielding ensures that external disturbances, such as those from motors or other electrical devices, do not affect data transmission. The 250 MHz bandwidth allows data transmission at speeds up to 1000 Mbit/s (Gigabit-Ethernet) over the specified distance. The use of rigid copper conductors ensures high mechanical stability and uniform conductivity, maintaining signal quality along the entire cable length.
Compatibility and Accessories
The cable is compatible with standard network devices supporting Cat6 connectors. It can be connected with RJ45 connectors designed for Cat6A or Cat8, although the actual performance is limited by the cable’s lower bandwidth. Suitable accessories include field-terminated TP connectors in Cat6A or Cat8 quality, cable organizers, hook-and-loop cable ties, and tools such as side cutters. These components facilitate installation and ensure proper use within the network.
Installation and Mounting
Installation typically takes place in cable ducts, wall-mounted runs, or underfloor. Due to the rigidity of the conductors, the cable is not suitable for frequent bending or movement. Installation requires appropriate tools, such as side cutters, to cleanly cut the conductors. Connection to network devices is made via RJ45 connectors, which can be terminated either tool-free or with tools. The use of cable organizers and cable ties ensures orderly routing and prevents cable management issues.
Operational Advantages
The high interference resistance provided by dual shielding ensures reliable data transmission, even in sensitive environments. The halogen-free construction increases safety in case of fire. The use of rigid copper conductors ensures stable signal transmission over the entire cable length. The cable is designed for structured cabling systems and meets the requirements of modern networks with high data rates.