VDE-Kabel P047006

VDE-Kabel P047006 N2XH-J 5x1,5 RE halogenfree

Cables > Halogen-free cables and wires > Halogen-free cables N2XH

VDE-Kabel P047006 N2XH-J 5x1,5 RE halogenfree

Lieske Part No. 822397
Mfg Part No P047006
EAN-Code
Manufacturer VDE-Kabel
Here only 2,07 EUR
2,46 EUR incl. VAT

Further information for VDE-Kabel P047006 N2XH-J 5x1,5 RE halogenfree

General
Nominal voltage0,6/1 kV
Test voltage4000 V
Operation temperature+90 °C
Installation temperature-5 to +70 °C
Operating temperature after installation-30 to +70 °C
Bend radius single-core15 x cable diameter
Bending radius multi-core12 x cable diameter
Conductor typeRound solid (RE)
Number of cores5
Conductor cross section1,5 mm²
Wire insulationcross-linked polyethylene (2XI1)
Outer sheathhalogen-free polymer blend
Sheath colourBlack
Burning behaviouraccording to VDE 0472 T. 804, test type C
Corrosivity of fire gasesaccording to VDE 0472 T. 813
Flue gas densityaccording to VDE 0472 T. 816, test type C
Halogen-freeAccording to VDE 0472 Part 815
Ozone resistanceAccording to VDE 0472 T. 805
InstallationNot directly in earth or water
Application rangeindoor and outdoor use
The cable N2XH-J 5X1.5 RE from VDE-Kabel is a halogen-free, protection-insulated wiring cable designed for applications with high safety requirements. It is used wherever the protection of people and property from fire and fire damage is of decisive importance. The cable is suitable for use indoors and outdoors, but not for direct installation in earth or water. Under flame exposure, it prevents the spread of fire and emits only extremely low amounts of smoke. It does not release corrosive or toxic gases, making it particularly suitable for areas with high visitor traffic or sensitive technical installations.

Applications
This cable is intended for use in buildings with enhanced fire protection requirements, such as hospitals, administrative buildings, schools, office complexes, or industrial facilities. It is suitable for supplying electrical devices, lighting systems, controls, and safety systems, where a safe and reliable power supply must also be guaranteed in the event of fire. Outdoor use is possible, provided the environmental conditions meet the specified temperature and bending requirements.

Functions and Features in Detail
The cable consists of bare copper conductors according to VDE 0295, executed as round single-strand (RE). The conductors are insulated with cross-linked polyethylene (2XI1), ensuring high thermal and mechanical stability. The conductor identification follows VDE 0293-308, ensuring unambiguous identification of individual conductors. The outer sheath is made of a halogen-free polymer blend according to VDE 0207 T. 24 and is black in colour. This construction ensures high mechanical strength and chemical resistance.

Technology Explained Simply
The rated voltage is 0.6/1 kV, meaning the cable is designed for operating voltages up to 1 kV. The test voltage of 4000 V serves quality assurance and ensures the cable remains stable even under increased electrical stress. The maximum operating temperature is +90 °C, with installation permitted at temperatures from -5 °C to +70 °C. After installation, the cable can be operated at temperatures from -30 °C to +70 °C. The bending radius is 15 times the cable diameter for single-core conductors and 12 times for multi-core conductors, enabling flexible installation.

Compatibility and Accessories
The cable is designed for use in electrical installations complying with standards VDE 0295, VDE 0207 T. 24, and VDE 0472. It can be combined with other halogen-free cables meeting the same fire protection requirements. The use of suitable cable lugs, junction boxes, or switching devices is required to ensure a safe and durable connection. Additional conductor counts and cross-sections are available upon request.

Installation and Mounting
Installation is carried out indoors or outdoors, but direct installation in earth or water is not permitted. Installation must comply with the specified bending radii and temperature limits. Cable installation should be performed by qualified professionals to meet safety requirements. Conductors must be connected using appropriate connection elements complying with the respective standards.

Operational Advantages
The cable offers high fire protection, as it prevents flame spread and produces only minimal smoke. The absence of halogens and corrosive gases protects the environment and installed equipment. High thermal resistance and mechanical strength ensure long service life and reliable performance even under demanding conditions. The black-coloured outer sheath provides good visibility and is resistant to UV radiation and ozone, expanding outdoor application possibilities.