| General |
| Nominal voltage | 450/750 V |
| Test voltage | 2500 V |
| Installation temperature range | +5 °C - +70 °C |
| Temperature range after installation | -30 °C - +70 °C |
| Operation temperature | +70 °C |
| Bending radius | 15 x cable diameter |
| Flame retardancy | according to VDE 0472 Part 804, test type B (IEC 332-1) |
| Conductor | Copper bare, solid |
| Insulation | PVC according to VDE 0207 |
| Sheath colour | according to VDE 0293-308 |
The wiring cable H07V-U 1.5 BR from VDE-Kabel is a PVC-insulated single-core cable for use in electrical installations indoors. It is intended for installation in conduits, on, in, and under plaster, as well as in closed installation channels. The cable is also designed for internal wiring of devices, control panels, and distributors, and can be used in protected installations within and on luminaires. Direct installation on trays, gutters, or troughs is not permitted.
Applications
This cable is designed for use in indoor electrical installations, particularly in buildings with permanently installed power supplies. It is suitable for connecting electrical components in residential and commercial buildings, where stable and durable installation in conduits or installation shafts is required. Use in luminaires requires a protected environment to avoid mechanical or thermal stress.
Functions and Features in Detail
The cable consists of a bare, single-strand copper conductor, ensuring high electrical conductivity. The insulation is made of PVC, specified according to VDE 0207, to ensure sufficient electrical insulation and mechanical stability. The sheath color complies with the standard VDE 0293-308, ensuring uniform color coding within the installation. The brown color is typical for cables installed underground or in conduits.
Technical Explanation
The rated voltage of 450/750 V makes the cable suitable for use in power installations, for example, for supplying lighting, sockets, or small consumers. The test voltage of 2500 V ensures the electrical strength of the insulation. The maximum operating temperature is 70 °C, and during installation, the cable must withstand temperatures from +5 °C to +70 °C. After installation, it can be operated at temperatures from -30 °C to +70 °C, enabling use in indoor environments with varying climatic conditions. The minimum bending radius is 15 times the cable diameter to prevent mechanical damage to the conductor. Flame retardancy according to VDE 0472 Part 804, test method B (equivalent to IEC 332-1), ensures that the cable does not contribute to rapid flame spread in case of fire.
Compatibility and Accessories
The cable is designed for use with standard installation systems such as conduits, installation shafts, and distributors. It can be combined with other cables of the same type or compatible connection elements to build electrical circuits. Use in luminaires requires a mechanical and thermal protective environment, which must be provided by the luminaire’s construction.
Installation and Mounting
Installation is carried out by laying the cable in conduits or installation channels, ensuring the specified bending radii are observed to avoid damaging the cable. Installation must consider temperature requirements; the cable should not be laid at temperatures below +5 °C. After installation, the cable must be checked for electrical integrity, particularly regarding insulation strength.
Operational Advantages
The cable offers high electrical conductivity due to the bare copper conductor and reliable insulation through PVC. Flame retardancy increases safety in case of fire. Mechanical stability and a high bending radius facilitate installation in complex routing situations. Use in enclosed channels and conduits protects the cable from external influences and ensures a proper electrical installation.