| General |
| Nominal voltage | 300/500 V |
| Test voltage | 2000 V |
| Installation temperature range | +5 °C - +70 °C |
| Temperature range after installation | -30 °C - +70 °C |
| Operation temperature | +70 °C |
| Bending radius | 15 x cable diameter |
| Flame retardancy | VDE 0472 T. 804 test type B (=IEC 332-1) |
| Conductor | Copper bare, solid |
| Insulation | PVC according to VDE 0207 |
| Application | internal wiring of devices, protected installation in luminaires, conduits, on and under plaster, doorbell and signalling systems |
The wiring cable H05V-U 1.0 HBL RAL 5012 from VDE-Kabel is a PVC-insulated single-core cable for use in internal wiring of devices as well as for protected installation in and on luminaires, in conduits, on and under plaster. It is specifically designed for doorbell and signaling systems, and installation must be carried out under these conditions. The cable features a bare, single-strand copper conductor and PVC insulation in accordance with VDE 0207. The sheath color complies with standard VDE 0293-308 and is executed in light blue (RAL 5012).
Applications
The cable is designed for use in enclosed rooms and protected installation conditions. It is suitable, for example, for wiring of electrical devices, for connection cabling of luminaires, or for installation in conduit systems. However, its use is restricted to doorbell and signaling systems, meaning it is not suitable for general power applications or systems with higher voltages. Installation must be carried out under the condition that the ambient conditions meet the specified temperature and mechanical requirements.
Functions and Equipment in Detail
The cable consists of a single, bare copper conductor, ensuring a stable electrical connection. The PVC insulation provides sufficient electrical insulation and mechanical stability. The light blue color (RAL 5012) serves as visual identification and complies with VDE standards for color coding. The cable is rigid, meaning it is not designed for frequent bending, but for fixed installations in devices or systems.
Technology Explained Simply
The rated voltage is 300/500 V, indicating the maximum voltage at which the cable can be safely operated. The test voltage of 2000 V is used for quality testing and ensures that the insulation does not break down under increased voltage. The maximum operating temperature is +70 °C, and during installation, the cable must withstand temperatures from +5 °C to +70 °C. After installation, it can be exposed to temperatures from -30 °C to +70 °C. The minimum bending radius is 15 times the cable diameter to avoid damage to the insulation or conductor. Flame retardancy corresponds to test method B according to VDE 0472 Part 804 (equivalent to IEC 332-1), meaning the cable does not drip burning particles and does not propagate flame during a flame test.
Compatibility and Accessories
The cable is suitable for use in conjunction with other components of the same standard, particularly in systems designed for doorbell and signaling applications. Use with other cables or accessories is only meaningful if they also comply with VDE standard requirements.
Installation and Mounting
Installation must comply with the specified temperature and bending requirements. The cable is not suitable for movable applications due to its rigid nature. Installation is carried out in protected areas, for example in conduits or under plaster, with limited mechanical stress. Connections are made using appropriate terminals or plug connectors designed for a cross-section of 1.0 mm².
Operational Advantages
The cable provides a reliable electrical connection under low mechanical stress. The PVC insulation ensures high electrical insulation and mechanical stability. Color coding facilitates identification within the installation network. Flame retardancy according to VDE 0472 Part 804, test method B, increases operational safety, especially in enclosed rooms or systems with increased fire risk.