| General |
| Degree of protection | E90 |
| Nominal voltage | 300/500 V |
| Test voltage | 2000 V |
| Installation temperature range | +5 to +70 °C |
| Temperature range after installation | -30 to +70 °C |
| Bend radius single-core | 15 x cable diameter |
| Bending radius multi-core | 12 x cable diameter |
| Flame retardancy | EN 50266-2-4, IEC 60332-3 Cat.C |
| Insulation integrity | FE 180 |
| Circuit integrity | E 90 |
| Conductor marking | VDE 0293-308 |
| Outer sheath | halogen-free polymer blend orange |
| Conductor | Copper conductor, bare, solid or stranded |
| Wire insulation | networked halogen-free ceramisable insulation HXI2 |
| Features | halogen-free, flame-retardant, minimal smoke emission, no corrosive gases |
The VDE-Kabel NHXH 5X4 E90 is a halogen-free power cable specifically developed for applications with high fire protection requirements. It is intended for safe energy transmission in indoor environments and is designed for use in critical systems such as fire alarm systems, alarm systems, emergency lighting, and backup power supply in accordance with VDE 108. The cable features a cross-linked, ceramifiable insulation that ensures functional integrity in the event of fire. Testing according to DIN 4102-12 (E30) confirms that the cable remains functional even after 90 minutes of fire exposure. Conductor identification follows VDE 0293-308, enabling clear and unambiguous identification of the conductors. The outer sheath is made of a halogen-free polymer mixture in orange, ensuring good visibility and identification.
Applications
This cable is suitable for installation in indoor environments, particularly in air, concrete, or conduit, provided that water accumulation is avoided. Direct installation in earth or water is not permitted. It is intended for connecting devices of protection class II. The installation must ensure that the cable is protected against external mechanical influences. Typical application areas include buildings with enhanced safety requirements, such as hospitals, administrative buildings, schools, or public facilities, where the functionality of electrical systems during a fire is critical.
Functions and Equipment in Detail
The conductor is made of bare copper, either single-strand or multi-strand, ensuring high electrical conductivity and mechanical stability. The conductor insulation is made of cross-linked, halogen-free, ceramifiable insulation HXI2, which forms a ceramic layer in the event of fire, maintaining the insulation protection function. The common conductor sheathing provides additional mechanical and electrical stability. The orange outer sheath, made of halogen-free polymer mixture, offers high resistance to external influences and facilitates visual identification during installation.
Technology Explained Simply
The ceramification of the insulation at high temperatures ensures that the electrical insulation remains intact even during a fire. The E90 functional integrity test according to DIN 4102-12 means that the cable remains electrically functional for 90 minutes under fire exposure. Flame retardancy according to EN 50266-2-4 and IEC 60332-3 Cat.C indicates that the cable is difficult to ignite and does not propagate flames. The insulation integrity FE 180 according to VDE 0472 T. 814 guarantees that the insulation remains intact even after 180 minutes of fire exposure. The temperature range for installation is +5 °C to +70 °C, and after installation, it is -30 °C to +70 °C, allowing flexible use in various environments. The bending radius is 15 times the cable diameter for single-conductor and 12 times for multi-conductor conductors, enabling flexible installation without mechanical damage.
Compatibility and Accessories
The cable is suitable for use in standard cable support systems such as cable trays, cable ladders, and ceiling installations. It is compatible with devices of protection class II. Installation in conduit is permitted, provided water accumulation is avoided. The cable type is intended for use in systems according to VDE 108, particularly in fire alarm and emergency lighting systems. Design considerations must account for the fact that the conductor resistance at 800 °C (final temperature during E30 test) is approximately four times higher than at 20 °C, which must be considered during dimensioning.
Installation and Mounting
Installation is carried out indoors, with possible routing in air, concrete, or conduit. Direct installation in earth or water is not allowed. Cables must be protected against mechanical damage and external influences. Bending radii must be observed to avoid damage to the conductor or insulation. Installation in conduit requires measures to prevent water accumulation. Conductor identification according to VDE 0293-308 facilitates correct assignment of conductors.
Operational Advantages
The cable provides high safety in the event of fire through functional integrity E90 and ceramifiable insulation. The halogen-free composition prevents the release of toxic and corrosive gases and dense smoke. The flame-retardant effect and minimal smoke development increase safety for personnel and property. The high electrical conductivity of the copper conductor and stable insulation ensure reliable energy transmission. The orange color of the outer sheath facilitates identification and maintenance during operation.