General
Nominal voltage300/500 V
Test voltage2000 V
Installation temperature range+5 °C
Temperature range after installation-30 °C
Bend radius single-core15 x cable diameter
Bending radius multi-core12 x cable diameter
Flame retardancyEN 50266-2-4, IEC 60332-3 Cat.C
Insulation integrityFE 180 according to VDE 0472 Part 814
Circuit integrityE 30 according to DIN 4102-12
Conductor materialCopper
Insulation materialnetworked halogen-free ceramising 2-layer insulation HXI2
Conductor markingVDE 0293-308
Sheath colourOrange
Sheath materialhalogen-free polymer blend
Featureshalogen-free, flame-retardant, minimal smoke emission, no corrosive gases
The NHXH 3X1.5 E30 cable from VDE-Kabel is a halogen-free power cable specifically developed for applications with high fire protection requirements. It ensures safe power supply in buildings where the protection of people and property in the event of fire is crucial. The cable is intended for indoor use, particularly for aerial or concrete installation, and can also be installed in conduits, provided no water accumulation occurs. Direct installation in earth or water is not permitted. It is suitable for connecting devices of protection class II and meets the requirements for functional integrity according to DIN 4102 Part 12 (E30), qualifying it for use in fire alarm systems, alarm and instruction systems, as well as safety and emergency lighting in accordance with VDE 108. The design of cable systems with functional integrity requires consideration that the conductor resistance at 800 °C (final temperature in E30 test) is approximately four times higher than at 20 °C.

Applications
This cable is used in areas where high fire resistance and functional integrity during a fire are required. This includes buildings with high visitor traffic, such as hospitals, schools, administrative buildings, or public transport facilities. It is suitable for installation in cable trays, cable ladders, and ceiling installations. Its use in fire alarm systems, safety lighting, and other emergency power supplies is permitted due to the passed E30 test. Cable installation takes place indoors, with mechanical damage and external influences to be excluded by appropriate protective measures.

Functions and Equipment in Detail
The cable consists of bare copper conductors, which are either single-strand or multi-strand. The core insulation is made of a cross-linked, halogen-free, ceramizing two-layer insulation (HXI2), providing high thermal resistance and optimized fire behavior. Core identification follows VDE 0293-308, enabling clear identification of the cores. The common core sheathing protects individual cores and ensures structural stability. The outer sheath is orange and made of a halogen-free polymer blend, supporting fire behavior properties.

Technology Explained Simply
The halogen-free composition of the cable prevents the release of toxic and corrosive gases during a fire. The ceramizing insulation forms a protective ceramic layer at high temperatures, maintaining electrical insulation. The functional integrity test according to DIN 4102-12 (E30) means the cable maintains its electrical function for at least 30 minutes at a fire temperature of 800 °C. Flame retardancy according to EN 50266-2-4 and IEC 60332-3 Cat.C, along with insulation integrity FE 180 according to VDE 0472 T. 814, ensures reliability during a fire. The rated voltage is 300/500 V, the test voltage is 2000 V. Temperature ranges are +5 °C to +70 °C during installation and -30 °C to +70 °C after installation. The bending radius is 15 times the cable diameter for single-core and 12 times for multi-core cables.

Compatibility and Accessories
The cable is suitable for use in standard cable support systems such as cable trays, cable ladders, and ceiling installations. It can be installed in conduits, provided no water accumulation occurs. Its use in fire alarm systems, safety lighting, and emergency power supplies is permitted due to the passed E30 test. Cable installation requires protection against mechanical damage and external influences. Design must account for increased resistance at high temperatures.

Installation and Mounting
Installation is carried out indoors, with permitted installation methods including aerial, concrete, or conduit (without water accumulation). Cables must be protected against mechanical damage. Installation in earth or water is not allowed. Bending radii must be observed: 15 times the diameter for single-core and 12 times for multi-core cables. Temperature limits during installation (+5 °C to +70 °C) and after installation (-30 °C to +70 °C) must be respected.

Operational Advantages
The cable offers high safety during fire events due to halogen-free, ceramizing insulation and passed E30 test. Minimal smoke development and no release of corrosive gases protect people and equipment. Functional integrity for 30 minutes at 800 °C ensures reliability of safety systems. Permitted use in fire alarm systems, safety lighting, and emergency power supplies increases application versatility. The cable is suitable for connecting devices of protection class II.

Functional Integrity E30
The functional integrity test according to DIN 4102-12 (E30) ensures the cable maintains its electrical function for at least 30 minutes under fire conditions. This is critical for the functionality of safety systems such as fire alarm systems, emergency lighting, and alarm systems. The test is conducted under standardized conditions, with the cable exposed to a temperature of 800 °C in a fire furnace. The insulation must maintain electrical separation between cores, and conductors must ensure current transmission. The test covers all standard cable support systems such as cable trays, cable ladders, and ceiling installations. A test certificate from an official material testing institute can be provided upon request.

Flame Retardancy and Insulation Integrity
Flame retardancy according to EN 50266-2-4 and IEC 60332-3 Cat.C means the cable does not continue to burn after the ignition source is removed. Insulation integrity FE 180 according to VDE 0472 T. 814 ensures the insulation maintains electrical insulation even after an 180-minute fire test. These properties are essential for safety in buildings with high fire protection requirements.

Material and Environmental Compatibility
The cable is halogen-free, meaning it does not release toxic halogen compounds during a fire. The ceramizing insulation forms a protective ceramic layer at high temperatures, maintaining electrical insulation. Minimal smoke development and no release of corrosive gases protect people and equipment. The outer sheath is orange and made of a halogen-free polymer blend, supporting fire behavior properties. The use of copper conductors ensures high electrical conductivity and durability.