| General |
| Conductor diameter | 0,8 mm |
| Conductor marking | in accordance with VDE 0815 |
| Insulation material | networked halogen-free ceramifiable polymer blend |
| Screening | Polyester-laminated aluminium tape with twin wire 0.8 mm |
| Outer sheath | halogen-free polymer blend |
| Outer sheath colour | Red |
| Nominal voltage | 225 V |
| Temperature range for installation | -5 to +50 °C |
| Operating temperature range | -30 to +70 °C |
| Bending radius | 7,5 x cable diameter |
| Flame retardancy | EN 50266-2-4, IEC 60332-1, IEC 60332-3 Cat.C |
| Insulation integrity | FE 180 according to VDE 0472 T. 814-IEC 60331 |
| Circuit integrity | E 30 according to DIN 4102-12 |
| Features | halogen-free, flame-retardant, minimal smoke emission, no corrosive gases |
The VDE-Kabel BMK JE-H(ST)H 12X2X0,8 E30 RT is a halogen-free communication cable designed specifically for use in control and regulation systems as well as fire alarm systems. This cable is intended for signal and measurement value transmission and is suitable for applications where the system must maintain functionality for a period of 30 minutes in the event of a fire. The cable is suitable for installation in dry and damp operating environments, as well as in and under plaster. It is not approved for high-voltage installation purposes or for underground installation.
Applications
This cable is used in fire protection systems where the safety of people and property is paramount. It is particularly suitable for buildings with high fire protection requirements, such as hospitals, administrative buildings, or industrial facilities. The 30-minute functionality retention (E 30) ensures that the fire alarm system can continue transmitting signals even under fire conditions, which is crucial for early alarm and evacuation.
Functions and Equipment in Detail
The cable consists of single-strand, tinned copper conductors with a diameter of 0.8 mm. Each pair is insulated with a cross-linked, halogen-free, ceramizable polymer blend that turns into ceramic under heat, thereby maintaining electrical insulation even under fire conditions. The wire identification follows VDE 0815, with the base colors of the quartets in each bundle being fixed: Pair 1 blue-red, Pair 2 gray-yellow, Pair 3 green-brown, Pair 4 white-black. The individual bundles are marked with a numbered plastic helix to enable unique identification and assignment.
Technology Explained Simply
The stranding is structured as 2 conductors per pair, 4 pairs per bundle, with the bundles stranded in layers. A banding provides additional stability. The shielding consists of a polyester-laminated aluminum tape with a 0.8 mm twin wire, which reduces electromagnetic interference. The outer sheath is made of halogen-free polymer blend and is colored red, facilitating identification as a fire alarm cable. The rated voltage is 225 V. The cable can be installed at temperatures from -5 °C to +50 °C and is designed for operation from -30 °C to +70 °C after installation. The bending radius is 7.5 times the cable diameter.
Compatibility and Accessories
The cable is designed for use in fire alarm systems and meets the requirements for flame retardancy according to EN 50266-2-4, IEC 60332-1, and IEC 60332-3 Cat.C. The insulation retention (FE 180) is tested according to VDE 0472 T. 814-IEC 60331, meaning the insulation retains its electrical properties even at high temperatures. The functionality retention (E 30) is in accordance with DIN 4102-12, ensuring the cable’s performance during a fire for 30 minutes. The cable is halogen-free, flame-retardant, emits only minimal smoke, and does not release corrosive gases.
Installation and Mounting
Installation is carried out indoors, with the cable being laid in dry and damp operating environments, as well as in and under plaster. Installation is performed at temperatures between -5 °C and +50 °C. After installation, the cable is designed for operating temperatures from -30 °C to +70 °C. The bending radius is 7.5 times the cable diameter, allowing for flexible installation. The cable is not suitable for underground installation or high-voltage applications.
Operational Advantages
The halogen-free composition of the cable reduces the formation of toxic gases in the event of fire, increasing safety for personnel. The ceramizable insulation ensures that electrical functionality is maintained even at high temperatures. The shielding minimizes electromagnetic interference, improving signal quality in the system. The clear identification of wires and bundles simplifies installation and maintenance. The 30-minute functionality retention (E 30) ensures reliable signal transmission in emergency situations.