VDE-Kabel G036096

VDE-Kabel G036096 NHXCH 4X25/16 E30 cable

Cables > Halogen-free cables and wires > Buy Halogen-free cables NHXH / NHXCH E 30/90

VDE-Kabel G036096 NHXCH 4X25/16 E30 cable

Lieske Part No. 276251
Mfg Part No G036096
EAN-Code
Manufacturer VDE-Kabel
Here only 22,77 EUR
27,10 EUR incl. VAT

Further information for VDE-Kabel G036096 NHXCH 4X25/16 E30 cable

General
Nominal voltage300/500 V
Test voltage2000 V
Installation temperature range+5 °C
Temperature range after installation-30 °C
Bending radius12 x cable diameter
Flame retardancyEN 50266-2-4, IEC 60332-3 Cat.C
Insulation integrityFE 180 according to VDE 0472 Part 814
Circuit integrityE30 according to DIN 4102-12
Conductor markingVDE 0293-308
Wire insulationnetworked halogen-free ceramising 2-layer insulation HXI2
Outer sheathhalogen-free polymer blend orange
ConductorCopper conductor, bare, solid or stranded
Concentric conductorbare copper wire with retaining helix made of copper tape
Featureshalogen-free, flame-retardant, minimal smoke emission, no corrosive gases
Common core sheathingYes
PP tapeYes
The cable NHXCH 4X25/16 E30 from VDE-Kabel is a halogen-free power cable specifically developed for applications with high fire protection requirements. It ensures safe power supply in buildings, particularly in areas where the functionality of safety and emergency power systems must be guaranteed in case of fire. The cable is intended for indoor use, with installation in air, concrete, or conduits permitted, provided no water accumulation occurs in the conduit. Direct installation in soil or water is not allowed. The cable is suitable for connecting devices of protection class II and meets the requirements for functional integrity according to DIN 4102 Part 12 (E30), qualifying it for use in fire alarm systems, alarm and instruction systems, as well as safety and emergency lighting in accordance with VDE 108.

Applications
This cable is used in buildings with enhanced safety requirements, such as hospitals, administrative buildings, schools, or public facilities. It is particularly suitable for systems that must continue to function during a fire to protect human life and enable evacuation. The E30 functional integrity test guarantees that the cable remains electrically conductive even at high temperatures (up to 800 °C). It should be noted that the conductor resistance at 800 °C is approximately four times higher than at 20 °C, which must be considered during power supply planning.

Functions and Equipment in Detail
The cable consists of bare copper conductors, which are single- or multi-strand. The core insulation is made of a cross-linked, halogen-free, ceramizing two-layer insulation (HXI2), which forms a ceramic layer when heated, maintaining electrical insulation even during fire. Core identification follows VDE 0293-308. A common core sheathing protects the individual cores. A concentric conductor made of bare copper strands with a counter-wound copper tape helix ensures improved electrical conductivity and mechanical stability. A PP tape provides mechanical stabilization. The outer sheath is made of a halogen-free polymer mixture in orange color, protecting the cable against external influences.

Technology Explained Simply
The ceramization of the insulation is a key advantage: at high temperatures, the insulation undergoes a chemical change and forms a ceramic layer, maintaining electrical insulation even under fire conditions. This prevents short circuits and enables continued operation of connected systems. Testing according to DIN 4102-12 (E30) confirms that the cable maintains its electrical function for 30 minutes at an ambient temperature of 800 °C. Flame retardancy according to EN 50266-2-4 and IEC 60332-3 Cat.C, as well as insulation retention FE 180 according to VDE 0472 T. 814, underline its high fire protection performance. The halogen-free composition ensures that no toxic or corrosive gases are released in case of fire, minimizing smoke development and reducing risks to people.

Compatibility and Accessories
The cable is designed for use in standard cable support systems such as cable trays, cable ladders, and ceiling installations. It is suitable for use with devices of protection class II. Installation in conduits is permitted, provided no water accumulation occurs. Installation in soil or water is not allowed. The cable installation must be protected against external mechanical influences. The use of appropriate cable lugs, junction boxes, or other connection elements is required to ensure a safe and durable connection.

Installation and Mounting
Installation takes place indoors, with the ambient temperature during installation ranging between +5 °C and +70 °C. After installation, the temperature range of -30 °C to +70 °C is permissible. The minimum bending radius is 12 times the cable diameter to avoid mechanical damage. Cables must be protected against external influences such as mechanical stress, moisture, or chemical exposure. Installation should be carried out by qualified professionals who comply with the regulations of electrical codes and relevant building ordinances.

Operational Advantages
The NHXCH 4X25/16 E30 cable type offers high safety in case of fire through E30 functional integrity, minimal smoke development, and avoidance of corrosive gases. The halogen-free composition protects people and equipment. The ceramizing insulation ensures stable electrical performance even under extreme conditions. Use in safety systems such as fire alarm or emergency lighting systems guarantees functionality in emergencies. The cable is designed for use in buildings with high safety requirements and meets the relevant standards and tests.