General
Conductor diameter0,8 mm
Wire insulationPE -
Nominal voltage225 V
Loop resistance73,2 Ohm/km
Current carrying capacity5,1 A
Operating capacity55 nF/km
Insulation resistance5 GOhm x km
Capacitive couplings K3300 pF/400 pF at 800 Hz, 300 m
Line attenuation0,78 dB/km (800 Hz)
Installation temperature range-20 °C to +50 °C -
Temperature range after installation-30 °C to +70 °C -
Bending radius7.5 x cable diameter -
Sheath markingTelephone handset, white marking -
Conductor markingblack rings -
StrandingStar quad, basic bundle, main bundle -
SheathShielding layer made of aluminium tape with plastic coating, welded to PE sheath -
The cable of type A-2Y(L)2Y 20 X 2 X 0,8 is a telecommunication underground cable from the brand VDE-Kabel, specifically designed for outdoor installation and underground laying. It serves as a transmission medium for low-frequency telecommunication applications, particularly in telecommunications, and is used for example as a local loop or local connection cable, railway station telecommunication cable, or in industrial facilities. The construction is not approved for high-voltage installation purposes and requires additional protective measures when used in fire- or explosion-hazardous operating environments, as the outer PE jacket does not provide sufficient protection. Use in mines is restricted according to the requirements of DIN VDE 0118 Part 1 to Part 3.

Applications
This cable is designed for outdoor use and is suitable for installation in underground ducts, cable trenches, or other underground cable systems. It is primarily operated in the low-frequency range, especially in the trunk network and preferably unspooled. The application is in public and industrial telecommunication systems, where reliable and interference-free signal transmission over long distances is required. The cable construction is generally approved for use in operating environments, with specific restrictions applying to mining operations.

Functions and Equipment in Detail
The cable consists of single-strand, bare copper conductors with a diameter of 0.8 mm. The conductors are insulated with polyethylene (PE), ensuring high electrical insulation and mechanical stability. Conductor identification is achieved through black rings, enabling clear identification of individual conductors. The stranding is done in a star quad system: four conductors form a star quad, five star quads form a basic bundle, and five or ten basic bundles form a main bundle. These bundles are stranded to form the cable core, with a core wrapping present. The outer jacket consists of a layered jacket made of a 0.2 mm thick aluminium tape coated on both sides with plastic, and welded to a black PE jacket. The jacket marking is continuous with the inscription “Fernsprech-Handapparat” and a white meter marking, enabling length indication.

Technology Explained Simply
The rated voltage is 225 V, indicating the maximum voltage the cable can safely transmit. The loop resistance is 73.2 Ohm per kilometer, ensuring low signal attenuation. The current-carrying capacity is 5.1 A, indicating the maximum current the cable can safely carry. The operating capacitance is 55 nF/km, describing the electrical capacitance per unit length and relevant for signal transmission. The insulation resistance is 5 GOhm x km, indicating high insulation quality. The capacitive couplings (K3) are 300 pF/400 pF at 800 Hz and a length of 300 m, describing interference between conductors. The line attenuation is approximately 0.78 dB/km at 800 Hz, indicating signal attenuation over length. The temperature ranges for laying are between -20 °C and +50 °C, and after laying between -30 °C and +70 °C. The bending radius is 7.5 times the cable diameter, indicating the minimum curvature during laying.

Compatibility and Accessories
The cable is designed for use in existing telecommunication infrastructures and can be combined with other cables of the same type and standard. It is suitable for installation in underground ducts and cable trenches and requires no additional protective measures for outdoor laying. The cable construction is intended for use in industrial facilities and public telecommunication systems.

Installation and Mounting
Installation is carried out underground, with the specified temperature ranges to be observed. During laying, the temperature must not fall below -20 °C or exceed +50 °C. After laying, the temperature must not fall below -30 °C or exceed +70 °C. The bending radius is 7.5 times the cable diameter, which must be considered during bending and installation. The cable core is stranded, creating a stable structure. The core wrapping provides additional mechanical stability. Installation is typically performed by skilled personnel observing the regulations of DIN VDE 0816 Part 1.

Operational Advantages
The cable offers high electrical insulation and mechanical stability due to PE insulation and the layered jacket. The low line attenuation of 0.78 dB/km at 800 Hz ensures reliable signal transmission over long distances. The high current-carrying capacity of 5.1 A allows operation with higher currents. The operating capacitance of 55 nF/km and insulation resistance of 5 GOhm x km ensure stable and interference-free transmission. The meter marking facilitates length measurement and positioning during installation. Underground installation provides high mechanical protection and long service life.