Telecommunications installation cable J-YY ... Vol
according to VDE 0815
Application:
Preferably in the stations and private branch for
telecommunications equipment, in dry and damp rooms
as well as for
fixed installation on outer walls with protection from solar radiation.
Building:
Conductor: copper conductor, solid
blank
0.6 mm diameter
Wire insulation: PVC
marking:
according to VDE 0815
Stranding: 4 cores for Star
four
Star quad bundle to
bundle the cable core
Film
Sheath: Grey PVC
Specifications:
Rated voltage: 300 V
Test voltage: 800 V
DC loop resistance: 130 / km
Current Rating: 2.5 A
Operating capacity: 100 nF / km
Insulation resistance: 100 km Mx
Capacitive
Couplings: K1 (800 Hz, 100 m) 300pF
cable attenuation: 1.7 dB / km (800 Hz)
Temperature range: - 5 ° C - + 50 ° C
(during installation)
- 30 ° C - + 70 ° C
( after laying)
Operating temperature: + 70 ° C (max)
Bend Radius: 7.5 x cable diameter
2,5 x cable diameter
for single bending without
Train
Flame resistance according to VDE 0472 T. 804
test method B (= IEC 332-1)
Diameter in mm: 4 x 2 x 0.6
Outer diameter approx: 6.8
Cu index (kg / m%): 2.3 Type: I-YY 4X2X0, 6 Quantity: 1 MTR