Further information for Diverse J-Y(ST)Y 24X2X0,6 - JY (ST) 24x2x0 6 drum PVC insulated transmission line
Communication line JY (St) Y. .. Lg
according to VDE 0815
Application:
Preferably in the stations and extension
construction
within buildings, but also outdoors
. suitable for fixed installation in buildings
Building:
Conductor: solid bare copper conductor
0.6 mm or 0.8 mm diameter
Insulation: PVC
Marking: according to VDE 0815
stranding: cores to pairs
pairs in layers
of static
Screen: plastic laminated metal foil
with drain wire, foil
Sheath: Grey PVC
Specifications: 0.6 mm 0.8 mm
Rated voltage: 300 V 300 V
Test voltage: 800V 800V
Loop resistance: 130 / 73.2 km / km
Current Rating: 2.5 A 5.1 A
Operating capacity: 120 nF / km 100 nF / km
Insulation resistance: 100 km Mx Mx 100 km
Capacitive
Couplings: K1 (800 Hz, 100 m)
300pF 300pF
cable attenuation: 1.7 dB / km 1.1 dB / km
(800 Hz)
Temperature range: - 5 ° C - + 50 ° C (during installation)
- 30 ° C - + 70 ° C (after installation)
Operating temperature: + 70 ° C (max.)
Bending radius: 7,5 x cable diameter
2.5 x cable diameter
for single bending without train
Flame resistance according to VDE 0472 T. 804
Category B (= IEC 332-1)
Weight (kg / m%): 23.5
Diameter in mm: 24 x 0.6 x 2
Outer diameter approx: 12.5
Copper weight (Kg / m%): 13.9 Type: IY (ST) Y 24x2x0, 6
Quantity: 1 MTR