| General |
| Loop conductor resistance | 130 Ohm/km |
| Insulation resistance | 5 GOhm x km |
| Operating capacity | 52 nF/km |
| Test voltage core/core | 800 V |
| Test voltage core/shield | 2000 V |
| Operating peak voltage | 300 V |
| Temperature range in motion | -5 to +50 °C |
| Temperature range stationary | -30 to +70 °C |
| Bending radius | 7.5 x cable diameter |
| Capacitive coupling K9-K12 | 300 pF/300 m |
| Capacitive coupling K1 | 800 pF/300 m |
| Near-end crosstalk 2x2 | 45 dB |
| Near crosstalk attenuation from 4x2 | 25 dB |
| Characteristic impedance | 100 Ohm |
| Attenuation 1 MHz | -35 dB/km |
| Attenuation 4 MHz | -55 dB/km |
| Shaft damping 10 MHz | -73 dB/km |
| Wave attenuation 16 MHz | -86 dB/km |
| Flame retardancy | VDE 0482-332-1-2/IEC 60332-1 |
| Conductor diameter | 0,6 mm |
| Wire insulation | PE |
| Outer sheath | PVC grey |
| Shielding type | Static shield with plastic-laminated metal foil and twin wire |
| Stranding | conductors twisted into star quad, 5 quads into bundle, bundles in layers |
| Marking | according to VDE 0815/colour+rings |
| Application range | Indoor installation, in or under plaster, on cable trays |
| Maximum span length | 120 m |
The telecommunications cable type J-2Y(ST)Y 20X2X0.6 from VDE-Kabel is a PVC-insulated installation cable for use in data processing systems, communication systems, and data transmission electronics. It serves as a connection and interconnection cable for indoor installation, for example, in or under plaster, or on standard cable carriers. The maximum achievable length is 120 meters. The cable is not intended for high-voltage installations or direct earth burial.
Applications
The cable is designed for use in indoor environments, where it connects end devices, network equipment, or other data communication components. It is suitable for data transmission applications with bandwidths up to 16 MBit/s, with technical specifications ensuring stable signal transmission within the specified range. Installation takes place in enclosed spaces; the cable is not designed for outdoor use or direct earth burial.
Functions and Features in Detail
The cable consists of solid, bare copper conductors with a diameter of 0.6 mm. Each conductor is insulated with PE (polyethylene) and marked according to VDE 0815 by color and rings. The conductors are twisted into star quads, with five such quads bundled together. These bundles are arranged in layers. A static shield made of plastic-laminated metal foil with a twin wire protects the cable from electromagnetic interference. The outer sheath is made of gray PVC, providing mechanical protection and ensuring flame retardancy in accordance with VDE 0482-332-1-2/IEC 60332-1.
Technology Explained Simply
The loop resistance is a maximum of 130 Ohm per kilometer, ensuring low signal attenuation. The insulation resistance is at least 5 Gigaohm per kilometer, ensuring high electrical insulation and thus low failure susceptibility. The operating capacitance is up to 52 nF per kilometer at 800 Hz, ensuring stable impedance and minimal signal distortion. The test voltage between conductors is 800 V, and between conductor and shield is 2000 V, each at 50 Hz for one minute. The operating peak voltage is limited to 300 V. The cable can withstand temperatures from -5 °C to +50 °C for moving installations and from -30 °C to +70 °C for fixed installations. The bending radius is 7.5 times the cable diameter. Capacitive coupling is up to 300 pF/300 m for cable groups K9 to K12 and up to 800 pF/300 m for K1. Near-end crosstalk attenuation is at least 45 dB for 2 x 2 conductors and at least 25 dB for 4 x 2 conductors. The characteristic impedance is 100 Ohm ±15 %, ensuring good impedance matching. Attenuation is up to -35 dB/km at 1 MHz, -55 dB/km at 4 MHz, -73 dB/km at 10 MHz, and -86 dB/km at 16 MHz. Flame retardancy complies with VDE 0482-332-1-2/IEC 60332-1, limiting flame spread in case of fire.
Compatibility and Accessories
The cable is suitable for data transmission systems with bandwidths up to 16 MBit/s. It is compatible with standard network equipment requiring 100 Ohm impedance. Use in high-voltage installations or direct earth burial is not intended. The cable can be connected using standard connectors and couplings designed for telecommunications cables with 0.6 mm conductor diameter.
Installation and Mounting
Installation is carried out indoors, with the cable laid in or under plaster or on cable carriers. The bending radius requirement of 7.5 times the cable diameter must be observed to avoid mechanical damage. The cable is not designed for movable applications or outdoor use. Installation requires no additional protective measures, as the PVC outer sheath and static shield provide sufficient protection.
Operational Advantages
The cable offers high signal quality due to the static shield and precise twisting of the conductors. Flame retardancy according to VDE 0482-332-1-2/IEC 60332-1 increases safety during operation. Low attenuation and stable characteristic impedance ensure reliable data transmission over the entire range of up to 120 meters. High insulation strength and low conductor resistance minimize errors and signal losses. The cable is designed for use in standardized indoor installations, allowing easy integration into existing infrastructures.