| General |
| Conductor diameter | 0,6 mm |
| Conductor material | Copper - |
| Insulating material | PE - |
| Outer sheath material | PVC - |
| Outer sheath colour | Grey - |
| Shielding type | static shield with plastic-laminated metal foil and twin wire - |
| Loop conductor resistance | max 130 Ohm/km |
| Insulation resistance | min. 5 GΩ·km |
| Operating capacity | max 52 nF/km |
| Test voltage core/core | 800 V |
| Test voltage core/shield | 2000 V |
| Operating peak voltage | 300 V |
| Temperature range in motion | -5 to +50 °C |
| Temperature range stationary | -30 to +70 °C |
| Bending radius | 7.5 x cable diameter - |
| Capacitive coupling K9-K12 | max 300 pF/300 m |
| Capacitive coupling K1 | max 800 pF/300 m |
| Near-end crosstalk 2x2 | min. 45 dB |
| Near crosstalk attenuation from 4x2 | min. 25 dB |
| Characteristic impedance | 100 Ohm |
| Characteristic impedance tolerance | ±15 % |
| Attenuation 1 MHz | ≤ -35 dB/km |
| Attenuation 4 MHz | ≤ -55 dB/km |
| Shaft damping 10 MHz | ≤ -73 dB/km |
| Wave attenuation 16 MHz | ≤ -86 dB/km |
| Flame retardancy | VDE 0482-332-1-2/IEC 60332-1 - |
The cable J-2Y(ST)Y 2X2X0,6 from VDE-Kabel is a telecommunications installation cable for use in data processing systems and communication systems. It serves as a connection and interconnection cable for data transmission electronics and is intended for indoor installation, for example, in or under plaster, or on standard cable carriers. The maximum achievable length is 120 meters. The cable is not approved for high-voltage installations or underground installation.
Applications
The cable is designed for use in offices, server rooms, administrative buildings, and other indoor spaces where data communication over short to medium distances is required. It is suitable for connecting end devices such as PCs, printers, telephone systems, or network switches within a building. Installation takes place in enclosed rooms, with the ambient temperature during moving installation ranging from -5 °C to +50 °C, and during stationary installation from -30 °C to +70 °C.
Functions and Equipment in Detail
The cable features solid copper conductors with a diameter of 0.6 mm. The conductors are insulated with PE (polyethylene) and marked according to VDE 0815 by color and rings. The conductors are twisted into star quad configurations, with five such quads bundled together. These bundles are arranged in layers to ensure even distribution and mechanical stability. A static shield made of plastic-laminated metal foil with a twin wire protects the cable from electromagnetic interference. The outer sheath is made of gray PVC, ensuring mechanical stability and flame retardancy.
Technology Explained Simply
The cable is designed for data transmission in the frequency range up to 16 MHz. The characteristic impedance is 100 Ohm ±15 %, ensuring compatible impedance for standard data transmission systems. The attenuation is less than -35 dB/km at 1 MHz, less than -55 dB/km at 4 MHz, less than -73 dB/km at 10 MHz, and less than -86 dB/km at 16 MHz. These values guarantee sufficient signal transmission quality over the maximum length of 120 meters. Capacitive coupling is limited: between cable groups K9 to K12, it is maximum 300 pF/300 m, and between K1 and other groups, maximum 800 pF/300 m. The near-end crosstalk attenuation is at least 45 dB for two quads and at least 25 dB for four or more quads, ensuring minimal interference between conductors. The test voltage between conductors is 800 V/50 Hz/1 minute, and between conductor and shield is 2000 V/50 Hz/1 minute. The operating peak voltage is specified as 300 V. The loop resistance is maximum 130 Ohm/km, and the insulation resistance is at least 5 GOhm·km. The operating capacitance at 800 Hz is maximum 52 nF/km. The bending radius is 7.5 times the cable diameter.
Compatibility and Accessories
The cable is designed for use in systems requiring an impedance of 100 Ohm, as is common in many data communication systems. Flame retardancy according to VDE 0482-332-1-2/IEC 60332-1 ensures sufficient fire behavior tolerance in indoor environments. The cable is not intended for outdoor use or in damp environments, as no specific protection rating such as IP67 is specified. Installation is exclusively indoors, with mechanical stress from bending and pulling limited.
Installation and Mounting
Installation takes place in enclosed rooms, with the cable laid in or under plaster or secured to cable carriers. Bending radii must be observed to avoid mechanical damage. The cable is not suitable for underground installation or high-voltage systems. Connections are made using appropriate connectors or terminals designed for the conductor cross-section of 0.6 mm².
Operational Advantages
The cable provides reliable data transmission over distances up to 120 meters with low signal distortion and sufficient interference protection. The static shielding reduces electromagnetic influences, and the PE insulation ensures high insulation quality. Flame retardancy according to VDE 0482-332-1-2/IEC 60332-1 meets requirements for indoor use. The cable is designed for use in data processing systems and communication systems, with technical specifications ensuring stability and reliability throughout its entire service life.