Further information for Diverse A-2YF(L)2Y 10X2X0,8 - A 2YF (L) 2Y 10x2x0 8 ² water tight St III burial Bd VDE0816
Telephone cables for underground water-tight
O 2YF (L) 2Y ... St. Vol III to VDE 0816
Application:
The connection cable in local networks and PBX systems for
telephony and for the transmission of signals to be laid in
suitable ground, in cable ducts and pipes.
Building:
Conductor: solid bare copper conductor
0.6 mm or 0.8 mm diameter
Insulation: PE (2Y)
Core identification: with black rings
Stranding: 4 strands to star quad
5 star quad for basic bundle
each 5 or 10 sub units for
Main units and the and
Main beam to cable core
stranded.Jelly filling Seelenbe-
development
Jacket:
Coat layers = aluminum strip
0.2 mm with plastic beiseitig
and coated with the
PE jacket (black) welded
Sheath Marking: continuous telephone handset
and meter marking white
Specifications:
0.6 mm 0.8 mm
Rated voltage: 225 V 225 V
Test voltage: 2000 V 2000 V
Loop resistance: 130 Ohm / km 73.2 ohm / km
Current Rating: 2.5 A 5.1 A
Operating capacity: 52 nF / km 55 nF / km
Insulation resistance: 5 Gx Gx km 5 km
Capacitive coupling K3 (800 Hz, 300 m): 800pF/400pF
line attenuation (800 Hz) approx: 1.04 dB / km 0.78 dB / km
Temperature range: - 20 ° C - + 50 ° C (during installation)
- 30 ° C - + 70 ° C (after installation)
Bending radius: 10 x cable diameter
Number of pairs + sq mm cable-Ø: 10 x 2 x 0.8
Outer diameter approx: 15.5
Copper content (kg / m%): 10.1
Weight (kg / m%): 27.0 Type: A-2YF (L) 2Y 10x2x0, 8
Quantity: 1 MTR