Further information for Ubiquiti UA-SK-Elevator
Connects to readers in the elevator via PoE to authorize user floor selection. Support for up to 18 floors and digital inputs for vehicle status and emergency. (1) Elevator Hub
(1) G2 Reader
(2) 2-Wire PoE Extender
(10) Access CardsTechnical Specifications UA-Hub-Elevator
Mechanical Dimensions 129.3 x 244.7 x 33.6 mm (5.1 x 9.6 x 3,3 cm ( 1,3 inch )) Weight 537 g (1.2 lbs) Housing Material Polycarbonate Mounting Material Polycarbonate Hardware Network Interface (4) 10/100/1000 Base-T Management Interface (1) 10/100/1000 Base-T Power Method PoE++ Max. Power Consumption 7 W (excluding PoE output) PoE Input (1) PoE++, 50 VDC, 1.2 A PoE Output PoE Passthrough, (4) PoE, 50 VDC, 42 W total ESD/EMP Protection Air: ±8kV, Contact: ±4kV Digital Input (6) Vehicle Position Up/Down/Stop/Full/Door Open/Door Closed
(1) Emergency Outputs (18) Relay Rating
30VDC/2A LEDs System: white/blue/red.
Output Relay: white Buttons (1) Factory reset
terminal blocks Operating Temperature -10 to 40°C (14 to 104°F) Operating Humidity 5 to 95% non-condensing Certifications CE, FCC, IC UACC-Extender-2Wire-Tx/Rx
Mechanical Dimensions 40 x 105 x 25 mm (1.6 x 4.1 x 2,5 cm ( 1 inch )) Weight PoE Input: 77 g (2.7 oz)
PoE Output: 79 g (2.8 oz) Housing Material Polycarbonate Mounting Material Polycarbonate Hardware Network Interface (1) 10/100 MbE
(1) Homeplug AV Management Interface (1) 10/100 MbE Power Method PoE++ Max. Power Consumption 3 W (without PoE output) PoE Input (1) PoE++, 50 V DC, max. 1.2 A PoE Output (1) PoE+, 48 V DC, 0.72 A ESD/EMP Protection Air: ±8kV, Contact: ±4kV LED White Operating Temperature -10 to 40 °C (14 to 104 °F) Operating Humidity 5 to 95% non-condensing Certifications CE, FCC, IC UA-G2
Mechanical Dimensions 93 x 40 x 36.5 mm (3.7 x 1.6 x 3,6 cm ( 1,4 inch )) Weight 82 g (2.9 oz) Housing Material Polycarbonate, Glass Mounting In-wall, Distribution Box Weatherproof IP55 Hardware Network Interface (1) 10/100 MbE RJ45 port Connectivity BLE 4.1 Power method PoE
UL 294 Class 2 limited power supply
UL 60950-1/62368-1 LPS/PS2 power supply Supported voltage range 48V DC Max. power consumption 5W ESD/EMP protection Air: ±15kV, Contact: ±8kV Sensors Proximity sensor Speaker (1) 8 Ohm, 0.7 W LEDs R/G/B/W Button (1) Factory reset NFC frequency 13.56 MHz NFC reading range NFC standards ISO 14443A, 14443B, 15693 NFC technology NFC tag 1,2,3,4,5
MIFARE Classic
MIFAREPlus
MIFARE Ultralight
MIFARE DESFire Operating Environment Outdoor use Operating Temperature -30 to 45 °C (-22 to 113 °F) Operating Humidity 5 to 90% non-condensing Software Information A product's software version may be below UL 294 Level Destructive Attack: Level I
Line Safety: Level I
Endurance: Level I
Standby Power: Level I UL 294 Statement Compliance with IEEE 802.3 specifications has not been verified under UL 294.
The device is intended to comply with section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and 3 Circuits. PoE Cabling Requirements Cable 5e cabling is the recommended minimum power category. The power class used should be consistent with the transmission speed required at the installation site.
The minimum allowable conductor size for the connection between the PSE or power injector and the PD is 26 AWG (0.13 mm²) for patch cords 24 AWG (0.21 mm²) for horizontal or riser cords. CAN/ULC-60839-11-1 Class Grade Assignment: I Certifications CE, FCC, IC, UL 294, CAN/ULC-60839-11-1 Document Number and Issue Date and/or Revision Level UA-G2/UA-G2-Black, V02 LED System Solid blue: Adopted/device is ready. Solid white
: Adoption pending.
Flashing white/blue: Firmware is being updated
. Flashing red: Emergency lock UA Card
Mechanical Dimensions 85.6 x 54 x 0.8 mm (3.4 x 2.1 x 0,1 cm ( 0 inch )) Weight 5 g (0.18 oz) Format ISO 7810 ID-1 NFC Frequency 13.56 MHz NFC Technology ISO/IEC 14443 Type A
MIFARE DESFire
UniFi Access Proprietary Security Protocol