Further information for Triton RXA-04-AS4-CAX-A1 wall enclosure 4HE light grey
Technical data
Height packaging
0.230m
Recommended maximum load
25kg
Door height
180mm
Length packaging
0.400m
Width
550mm
Width packaging
0.550m
Depth
400mm
Colour
Grey (RAL7035)
Door width
505mm
Height (outside)
230mm
Weight
11.580kg
Height unit
4U
Packaging volume
0.0506m³
Protection class
IP30
Detachable rear panel
Demountable
Detachable side panels
The Triton RXA-04-AS4-CAX-A1 is a 48,3 cm ( 19 inch ) wall enclosure in 4 U format, designed for use in office environments. The housing is delivered disassembled and is constructed as a flat-pack, thereby reducing transport and storage costs. Assembly is carried out on a wall using screws, anchors, and washers, with an assembly time of approximately 5 to 10 minutes. The housing is made of sheet steel and is painted in light grey (RAL 7035). The front side is closed by a 4 mm thick safety glass door, equipped with a locking system and can be mounted to open on the right or left. The door is fitted with a hinge system that allows convenient access.
Applications
This wall enclosure is intended for the installation of data and telecommunication systems as well as their distribution systems. It is not suitable for outdoor use or for environments with explosion hazards, moisture, or dampness. Use is restricted to enclosed rooms that do not exert negative influences on the functionality of the housing or installed components. The recommended maximum load is 25 kg, which must be evenly distributed and the housing must be mounted on a load-bearing wall (e.g. brick or concrete wall).
Functions and Equipment in Detail
The housing features three cable entries – top, bottom, and rear – equipped with removable cover plates. These allow for flexible and neat cable routing. Ventilation slots provide passive ventilation to ensure adequate cooling of installed devices. The vertical mounting rails are depth-adjustable, enabling flexible adaptation to various devices. The rear panel and side panels are removable, facilitating access to the interior. An M8 screw is located in the housing base as the main earthing point. All parts are connected with earthing cables, which must remain properly secured and plugged in throughout the entire service life.
Technology Explained Simply
The enclosure is constructed in a disassembled design, with individual parts connected by plastic connectors. This reduces assembly time and minimizes tool requirements – only a Torx screwdriver (T25) is needed. Dimensions are 550 mm (width) × 230 mm (height) × 400 mm (depth), with a maximum installation depth of 300 mm. The protection class IP30 protects against solid foreign objects with a diameter greater than 2.5 mm and against splashing water, but not against direct water jets or immersion. The minimum coating thickness is 65 micrometers, ensuring surface quality and corrosion protection.
Compatibility and Accessories
The enclosure is compatible with various accessories suitable for optimal use. These include 48,3 cm ( 19 inch ) intermediate shelves in various depths (e.g. 150 mm, 250 mm), mounting kits with screws and cage nuts, cable management plates with brackets, and door hinges. Additionally, control centres for IP building automation, UPS systems, and cable ties can be used to extend the functionality of the enclosure.
Assembly and Installation
Assembly is carried out on a wall with sufficient load-bearing capacity. Fixing is done using the screws, anchors, and washers included in the delivery. The spacing for mounting is indicated in the distribution diagram with the value “R”. The permissible load capacity for individual doors is a maximum of 10 kg. The assembly is designed to be carried out without special tools or additional aids.
Advantages in Operation
The enclosure offers a compact and flexible solution for use in offices or technical rooms. The disassembled delivery reduces transport volume and costs. The depth-adjustable profile rails allow individual adaptation to different devices. The integrated earthing safety ensures safe operation. Cable entries and ventilation slots ensure proper cabling and cooling. The use of recyclable materials supports environmentally friendly disposal after decommissioning.