Further information for Triton RBA-18-AD5-BAX-A1 wall enclosure 18HE black
Technical data
Width
600mm
Length packaging
0.515m
Recommended maximum load
30kg
Depth
515mm
Protection class
IP20
Height packaging
0.900m
Weight
29.790kg
Door height
795mm
Colour
Black (RAL9005)
Door width
516mm
Height unit
18U
Packaging volume
0.2781m³
Height (outside)
900mm
Width packaging
0.600m
Detachable rear panel
Ventilation holes
Demountable
Detachable side panels
The Triton RBA-18-AD5-BAX-A1 is a 48,3 cm ( 19 inch ) wall-mounted enclosure with a height of 18 U, designed for use in data and telecommunication installations. The housing consists of a two-part, welded sheet metal enclosure in black (RAL 9005) with external dimensions of 600 mm (width) × 900 mm (height) × 515 mm (depth). It is directly mountable on the wall and features a robust construction capable of safely supporting a maximum load of 30 kg. The installation depth is up to 400 mm, making the enclosure suitable for use in rooms with limited space.
Applications
This wall-mounted enclosure is designed for use in IT infrastructures, such as in office buildings, server rooms, or for the installation of network and communication components. It is particularly suitable for mounting network devices, switches, routers, UPS systems, or process control systems that need to be installed in a closed, protective housing. The protection class IP20 ensures protection against contact with fingers and against solid foreign objects, but not against water or dust – thus, the enclosure is intended for indoor use only.
Functions and Features in Detail
The enclosure features a 4 mm thick safety glass door with a bronze finish, which can be mounted with either right- or left-hand hinges. The door can be opened up to 165° and is removable, facilitating access to installed components. The locking system is standardly keyed alike for both the door and the swing section. The doors are made of impact-resistant tempered safety glass, which shatters into small fragments if broken, minimizing injury risks. The glass doors comply with the standard CSN EN 12150-1+A and have been tested in a certified testing facility.
Technology Explained Simply
The vertical 48,3 cm ( 19 inch ) mounting rails are continuously adjustable in depth within the enclosure, enabling flexible device mounting and simplifying cable management. The mounting rails are pre-installed and made of a robust metal profile. At the bottom of the enclosure, there is an M8 screw serving as a central earthing point, and all removable parts are connected with earthing cables that must remain properly secured throughout the entire service life. This ensures safe and reliable earthing of the installed devices.
Compatibility and Accessories
The enclosure features six removable openings for cable entries in the roof, floor, and rear panel. These can be sealed with brush strips to exclude dust and foreign objects. The cable entries are equipped with edge protection to prevent cable damage. Compatible accessories include mounting kits with screws and cage nuts, 48,3 cm ( 19 inch ) intermediate shelves in various heights, Keystone module carriers, as well as UPS systems such as models CP2000EIPFCRM2U, CP1600EIPFCRM2U, and CP1200EIPFCRM2U. Additionally, process control systems like ALL3419, ALL3500v2, and ALL5000v2 are compatible and can be used for IP-based building automation.
Mounting and Installation
Wall mounting is achieved via a removable frame, enabling simple and secure attachment to the wall. The installation requires no additional tools beyond the provided screws and cage nuts. The pre-installed mounting rails simplify device installation, and the depth-adjustable rails allow optimal adaptation to device height. The maximum installation depth of 400 mm is sufficient for most standard devices.
Operational Advantages
The enclosure offers high stability due to its welded construction and reliable earthing. The safety glass door provides good visibility of installed components while ensuring protection against contact and dust. The flexible door opening and removable side and rear panels facilitate maintenance and device replacement. The integrated cable entries and brush strips support structured cable management and protect cables from mechanical stress. The protection class IP20 is suitable for use in dry indoor environments, and passive ventilation through ventilation slots provides sufficient cooling for most devices.