| Technical data |
| Height packaging | 0.100m |
| Length packaging | 0.500m |
| Mounting | 19" rackmount |
| Weight | 3.860kg |
| Colour | Grey (RAL7035) |
| Width packaging | 0.257m |
| Number of fans | 2 |
| Packaging volume | 0.0129m³ |
The Triton RAC-CH-X01-A1 is a 48,3 cm ( 19 inch ) ventilation unit for use in server and network racks. It is designed for targeted ventilation and cooling of IT and electronics components in 48,3 cm ( 19 inch ) rack systems. The unit is configured as a front-mount module and accommodates two fans that direct airflow from bottom to top. The unit is finished in Light Grey (RAL7035) and has a height of 2 U. The total depth is 222 mm, enabling compact integration into standard rack systems.
48,3 cm ( 19 inch ) Rackmount
The ventilation unit is designed for mounting in 48,3 cm ( 19 inch ) racks and is secured using screws and cage nuts. Installation takes place on the front side of the rack, making it ideal for cooling devices installed on the front panel of the rack. Thus, the unit is suitable for use in server and network racks where targeted airflow circulation is required.
Functions and Equipment in Detail
The unit features two fans that direct airflow from bottom to top. This airflow is particularly effective at removing heat from the lower sections of the rack and ensuring even temperature distribution. The unit is equipped with a thermostat that automatically turns the fans on and off depending on the temperature inside the rack. This ensures energy-efficient operation, as the fans only activate when the temperature exceeds a predefined threshold.
Technology Explained Simply
The ventilation unit operates at a voltage of 220 V and consumes 30 W of power. The fans are designed to generate continuous airflow, improving heat dissipation in the rack environment. The integrated thermostat monitors ambient temperature and controls the fans accordingly. This prevents unnecessary energy consumption and reduces noise when cooling is not required. The unit is designed for horizontal mounting, allowing seamless integration into the standard architecture of 48,3 cm ( 19 inch ) racks.
Compatibility and Accessories
The Triton RAC-CH-X01-A1 is specifically designed for standard distributors and can be mounted in the floor, ceiling, or door depending on requirements. For floor mounting, an additional mounting frame from the RAx-CHx-X1 series is required, which is attached using double-sided adhesive tape. Compatible accessories include a 48,3 cm ( 19 inch ) accessory fan unit, dual, with temperature control, 1 U, in Light Grey. This unit can be used additionally to increase cooling capacity in larger racks.
Mounting and Installation
Installation is performed on the front side of the rack. The unit is secured using four M6 x 10 screws, four plastic washers, and four M6 cage nuts. Installation is straightforward and does not require special tools. The screws and washers are included in the delivery. The unit is designed for quick and secure integration into the rack without requiring additional mounting aids.
Individual specifications such as packaging dimensions (length 0.500 m, width 0.257 m, height 0.100 m) or packaging volume (0.0129 m³) and weight (3.860 kg) are not relevant for operation and are only intended for logistics. The unit is designed for use in IT and electronics environments where reliable cooling is essential.
Advantages in Operation
The ventilation unit provides efficient cooling of IT and electronics components within the rack. The integrated thermostat enables automatic fan control, reducing energy consumption and extending the lifespan of devices. Front mounting and horizontal orientation facilitate easy integration into existing rack systems. The unit is robust and designed for professional environments. The Light Grey finish (RAL7035) matches the standard appearance of server racks.
The unit is designed for use in 48,3 cm ( 19 inch ) racks and is delivered with the necessary mounting materials (screws, washers, cage nuts). No additional components or tools are required for installation. Mounting is performed on the front side of the rack, making it ideal for cooling devices installed on the front panel of the rack.