The Triton power strip RAB-PD-X08-A1 is a 48,3 cm ( 19 inch ) mounting strip in 1HE format, specifically designed for use in server and network enclosures. It features eight grounded outlets (CEE7) and is equipped with a varistor surge protection device to protect connected equipment from transient voltage spikes. The strip is powered via a power cable with a grounded plug (CEE7), which has a length of 2 meters and a cross-section of 3x1.5 mm². The maximum current rating is 16 amperes at an input voltage of 230 volts. The housing is made of black plastic, corresponding to RAL 9005, and is designed for use in IT and electrical installations.
Applications
The power strip is intended for use in 48,3 cm ( 19 inch ) racks and server rooms, where a safe and organized power supply for multiple devices is required. It is particularly suitable for IT infrastructures, such as network switches, routers, servers, or other electronic components mounted in a rack. The 1HE form factor enables compact mounting in standard 48,3 cm ( 19 inch ) enclosures, while the eight outlets provide sufficient space for multiple devices. The integrated surge protection increases the safety of connected devices, especially in environments with unstable voltage or frequent lightning strikes.
Functions and Equipment in Detail
The strip provides eight grounded outlets (CEE7), manufactured according to DIN standards, ensuring a safe and standardized connection. The surge protection is based on varistor technology, which diverts voltage spikes and protects connected devices from damage. The supply cable, with a cross-section of 3x1.5 mm² and a length of 2 meters, is designed for stable power supply and features a grounded plug (CEE7) used in standard power outlets. The black color (RAL 9005) ensures seamless integration into existing rack systems.
Technology Explained Simply
The varistor surge protection responds to sudden voltage spikes caused by lightning strikes or network switching operations. It diverts excess energy without affecting normal power supply. The cable with a 3x1.5 mm² cross-section is rated for a maximum current of 16 amperes, sufficient for operating multiple IT devices. The 48,3 cm ( 19 inch ) form factor with 1HE conforms to the standard for rack mounting and allows easy installation in existing server or network enclosures.
Compatibility and Accessories
The power strip is designed for use in 48,3 cm ( 19 inch ) racks and fits standard 1HE mounting positions. It is compatible with devices connected via grounded plugs (CEE7). As accessories, additional 48,3 cm ( 19 inch ) power strips from ALLNET are available, also featuring 9 outlets and available in aluminum look or black. These can be used as supplements or alternatives, depending on requirements for the number of outlets or design.
Mounting and Installation
Mounting is done in a 48,3 cm ( 19 inch ) rack using the integrated mounting holes or fastening screws designed for the 1HE form factor. The supply cable with the grounded plug is connected to a suitable power outlet. Installation requires no additional tools or components, as the strip is simply inserted and secured in the rack. The outlets are designed for direct plug-in connection with devices.
Operational Advantages
The power strip provides reliable power supply for multiple devices in a rack, with the integrated surge protection offering additional safety. The 2-meter length of the supply cable allows flexible positioning within the rack. The 1HE form factor ensures compact mounting, saving space in the rack. The use of grounded outlets (CEE7) guarantees a safe and standardized connection, common in IT and electrical installations. The black color blends visually into existing rack systems.