Further information for Theo Benning Benning SET system and wallbox test All in One Passing 10236769 - SET Anlagen- und
SET system and wallbox testing all in one. Test device set for system and wallbox testing consisting of installation tester Benning IT 200 (044106), test adapter Benning EV 3-2 (044169) and L-Boxx 238 (10236016). Benning IT 200 Auto Sequence installation tester. Auto Sequence installation tester for testing electrical systems in accordance with DIN VDE 0100-600, IEC 60364-6 and DIN VDE 0105-100, EN 50110. With testing of FI/RCD circuit breakers type B/B+ all-current sensitive and type AC, A, F mixed frequencies as well as testing of e-charging stations (wallboxes) in accordance with VDE 0122-1, DIN EN/IEC 61851-1 of charging mode 3. Graphic display. Operation via 4.5-inch color touchscreen and push buttons. Limit value display yes. Measurements: Insulation resistance measurement yes. Insulation resistance 0.01 MOhm - 1000 MOhm. Nominal test voltage 50 V. Nominal test voltage 100 V. Nominal test voltage 250 V. Nominal test voltage 500 V. Nominal test voltage 1000 V. Autotest between the conductors LN-PE, Riso pre-test to protect connected devices. Resistances of insulating floors and walls yes. Low-resistance measurement yes. Low-resistance resistance 0.01 Ohm - 2000 Ohm, test current 200 mA with polarity reversal, and continuity, test current 7 mA. Earth measurement yes. Selective earth measurement yes. Earth loop measurement yes. Optionally using the 3-wire method via earthing set 044113 or the 2-clamp method via current clamp adapter BENNING CC 4-1 044166, BENNING CC 4-2 044167. Loop resistance/impedance measurement yes. Loop measurement without RCD/FI tripping yes. Loop impedance 0.01 Ohm - 10 kOhm L-PE and line impedance 0.01 Ohm - 10 kOhm LN/ L with 20 A test current including short-circuit current and voltage drop, loop impedance L-PE without FI/RCD tripping. Internal network resistance measurement yes, using the 3-wire method. Determination of short-circuit current/overcurrent protective devices yes. RCD/FI test yes. Curve shape for RCD/FI test for residual current circuit breakers type A, F and type B, B+. RCD/FI test with increasing residual current yes. RCD/FI analysis function yes. PRCD test type S, type K yes. Testing of RCD/FI circuit breakers standard and delayed S, type AC, A, F, B, B+, EV RCD/ EV RCM, RDC-DD, MI RCD and PRCDs with AUTO test, tripping time, tripping current with ramp test and contact voltage. Measuring leakage currents with adapter yes, optionally via current clamp adapter BENNING CC 4-1 044166. Testing of e-charging stations, simulation of vehicle status yes. Testing of e-charging stations, wall boxes via optional test adapter BENNING EV 3-2 044169, specially coordinated auto sequences for 1- and 3-phase wall boxes including functional testing/testing of the charging process, testing of EV-RCD and 6 mA DC residual current monitoring devices RDC-DD in accordance with IEC 62955 with measurement of the tripping time and tripping current, documentation via ready-made EVSE test reports. Rotating field test yes. Voltage measuring range AC/DC 1 V - 550 V. True RMS measuring method. Frequency measuring range 0.01 Hz - 500 Hz. Varistor test yes. First fault leakage current in the IT network. Current measurement yes,optionally via current clamp adapter BENNING CC 4-1 044166, BENNING CC 4-2 044167. True RMS measuring method. Power measurement yes, optionally via current clamp adapter BENNING CC 4-1 044166, BENNING CC 4-2 044167. Harmonic measurement yes, optionally via current clamp adapter BENNING CC 4-1 044166, BENNING CC 4-2 044167. Illuminance measurement yes, optionally via BENNING Luxmeter Type B 044111. Special features: Structured measured value memory yes. Measured value memory yes. Large measured value memory on 8 GB SD card. Individual tests and pre-programmed auto-sequence measurements. Auto tests at the touch of a button for Z Auto, RCD Auto, Auto-TN, -TN rcd, -TT, -IT. Order manager for managing test orders. Creation of complex system structures including planned measurements. User account management. Interface yes, USB, RS 232 and wireless interface Cordless-Link. Commander test plug for safety socket with good/bad display via green/red LED and TEST button. Connection for Barco