Further information for Telecom Behnke 20-0002A-IP - Electronic compact (SIP) size 3
• Basic Electronics Size 2 for door stations with locally remote electronics
• Connection of up to 8 call buttons, 1 dial pad, 1 display, 1 speaker, 1 microphone
• 2 relays (max. Switching capacity: 2 A / 30 VDC, 0.5 A / 40VAC): 1 NO contact, 1 changeover contact
• 1 alarm input (input voltage 10 V = max. 15 V =)
• RJ45 port for 100BaseT Ethernet, alternatively by means of screw (EIA / TIA 568 A)
• Additional RJ45 port for connecting additional IP devices such. B. IP camera (no screw)
• Large housing (possibility to install an electronic extension)
• Dimensions (H x W x D): 292 x 97 x 37 mm
Electronics: • voice communication via Voice over IP (VoIP) to the SIP standard via the connected Ethernet LAN using a SIP-enabled PBX, a SIP provider or direct dial an IP address
• Configuration and software updates via web browser
• Power supply: Power over Ethernet (PoE) according to IEEE 802.3af
• integrated PoE switch (VLAN support) for the connection of a PoE-enabled terminal with a max. Power of 7 W
• Full-duplex operation (integrated acoustic echo cancellation)
• Sammelruffunktion / Redial
• Status / remote control messages to integrate with third-party software
• 9 voice prompts, each with up to 40 seconds long storable
• 16 MB shared memory for phonebook flash and voice prompts
• Configuration file can be saved in
Technical specifications
network
• MAC address (IEEE 802.3)
• IPv4 - Internet Protocol Version 4 (RFC 791)
• ARP - Address Resolution Protocol
• DNS - A record (RFC 1706)
• DHCP Client - Dynamic Host Configuration Protocol (RFC 2131)
• TCP - Transmission Control Protocol (RFC 93)
• UDP - User Datagram Protocol (RFC 768)
• RTP - Real Time Protocol (RFC 1889) (RFC 1890)
• RTCP - Real Time Control Protocol (RFC 1889)
• DiffServ (RFC 2475), Type of Service (RFC 791, RFC 1349)
• SNTP - Simple Network Time Protocol (RFC 2030)
• SIPv2 - Session Initiation Protocol version 2 (RFC 3261, 3262.3263, 3264)
• SIP in NAT networks (STUN)
• Autoprovisionierung via DHCP Option 66 or send us a configured server
• Backup SIP server configurable
• Firmware update via web interface
• Integrated PoE switch with support for tagged VLANs
Speech codecs
• G.711 (A-law, µ-law)
• G726 (32 kbps)
• G.721
• DTMF in-band and out-of-band (RFC 2833), SIP Info
• Full-duplex, echo suppression (AEC)
• speaker volume in 10 levels configurable
• microphone sensitivity to 10 levels configurable
Electrical characteristics
• Power supply via Power over Ethernet (PoE) according to IEEE803.3af
. • Max Power Consumption: 12 W
• SIP station: 5 W
• device to PORT2: max. 7 W
• Max. Switching capacity of relay: 2 A / 30 VDC, 0.5 A / 40VAC
• Input voltage alarm input: 10 V max. 15 V
• Operating temperature: -20 ° C to + 50 ° C