Further information for TCS AZF50000-0010 code lock 10 codes silver
General
Product depth
16 mm
Housing material
Aluminium profiles
Number of access codes
10
Maximum code length
6 digits
Operating voltage door opener
24 V DC
Maximum operating current door opener
2 A
Input current (2-wire)
1,7 mA
Input current (3-wire)
0,4 mA
Standby current (3-wire)
1,3 mA
Maximum input current
36 mA
Permissible ambient temperature
-20 to 50 °C
Keyboard area colour
natural anodized
Programming
Manual
Status indicator
LEDs
Acknowledgement on code entry
optical and acoustic
Mounting system
win:clip principle
Master code
Sabotage contact
TCS-BUS compatible
The TCS code lock AZF50000-0010 is an access control system for use in security technology applications. It enables electronic door unlocking using up to 10 individually configurable access codes, each of which can be up to six digits long. The device is designed for use in buildings with increased security requirements and is particularly suitable for use in office buildings, residential complexes, or industrial facilities where controlled access authorization is required.
Applications
This code lock is suitable for use in indoor environments as well as protected outdoor areas, as it tolerates ambient temperatures from -20 °C to 50 °C. The product depth of 16 mm allows for a slim installation in doors, making it suitable even for doors with limited space. The win:clip principle ensures simple and quick installation without additional tools. The housing is made of robust aluminium profiles, ensuring high mechanical stability and durability.
Functions and Equipment in Detail
The device features a keyboard with a natural anodized surface, which is both aesthetically pleasing and resistant to dirt and wear. Upon code entry, an optical and acoustic confirmation is provided, achieved through integrated LEDs and a speaker. This allows the user immediate feedback on whether the entered code was correct. An anti-tamper contact is integrated to trigger an alarm signal in case of physical manipulation or damage to the device. Programming is done manually, with a master code provided for maintenance and system configuration.
Technology Explained Simply
The code lock operates with a potential-free relay contact (changeover) for door unlocking, which can be powered with 24 V DC and a current of up to 2 A. This allows control of door openers typically used in security technology systems. Power supply is via a 2-wire or 3-wire system. In 2-wire operation, the input current is 1.7 mA; in 3-wire operation, 0.4 mA for operating current and 1.3 mA for standby current. The maximum input current is 36 mA. The TCS-BUS capability enables integration into larger access control systems, allowing the device to communicate with other components.
Compatibility and Accessories
The device is designed for use in systems with TCS-BUS technology, enabling connection to other TCS components. The door opener function can be connected to standardized door openers operated via a changeover contact with 24 V DC and 2 A. The individual trigger functions of the access codes allow for differentiated control, for example, for different times of day or authorization levels.
Installation and Mounting
Mounting is done via the win:clip principle, enabling quick and tool-free attachment to the door. The device dimensions are 153 mm (height) × 104 mm (width) × 16 mm (depth), allowing integration into most standard door constructions. Installation does not require special tools, but proper wiring is necessary to ensure functions such as door unlocking and tamper detection.
Advantages in Operation
The code lock offers high user-friendliness through clear optical and acoustic feedback during code entry. The ability to manage up to 10 individual codes with different functions enables flexible use. Integration into TCS-BUS systems allows central control and monitoring. The robust aluminium construction and low product depth ensure a long-lasting and space-saving installation.