| Technical data |
| CAT | CAT6A |
| Sheath | LSZH (halogen-free) |
| Shielding | S-STP(S/FTP) pair foil shielded |
| Length | 2m |
| Colour | Black |
| Connector type | Long |
| Cable type | Round |
| AWG (single conductor size) | 26 |
| POE cable power | POE/POE+/POE++ |
| MHz | 500Mhz |
| Cable outer diameter mm | 6.20 |
The patch cable from the brand Synergy 21, manufacturer's number S216494, is a
Cat6A data cable with a length of 2 metres, designed for use in modern network infrastructures. It features
S-STP (S/FTP) shielding, where each pair of conductors is protected by a foil shield and additionally by an overall braid shield, ensuring high immunity against electromagnetic interference. The cable is equipped with
RJ45 connectors at both ends, featuring strain relief protection to ensure a secure and mechanically stable connection. The connectors are designed as
long, enabling better fit in standard network sockets. The cable jacket is made of
LSZH material (halogen-free), which does not release toxic gases in case of fire, making it suitable for use in enclosed spaces and buildings with high safety requirements. The cable colour is
black, allowing it to blend inconspicuously in typical IT and network applications.
Applications
This patch cable is designed for use in networks with high requirements for bandwidth and signal integrity. It is particularly suitable for connecting switches, routers, network devices, and end devices such as computers, monitors, or IP cameras. Category 6A enables data transfer rates up to 10 Gbit/s over a distance of up to 100 metres in channel mode, with the specified length of 2 metres well below this limit. The frequency bandwidth of
500 MHz ensures stable transmission even at high data rates. The cable is intended for indoor use and complies with the standards
ISO/IEC 11801 Class Ea Channel Link,
EN 50173-1, and
ANSI/TIA-568-C.2, guaranteeing compliance with international standards for network cables.
Functions and Equipment in Detail
The cable is constructed with
AWG 26 individual conductor gauge, ensuring sufficient conductivity for transmitted signals. The
S/FTP shielding (Separate Foil Twisted Pair) protects each conductor pair individually with a metallic foil and is supplemented by an outer braid that encloses the entire cable structure. This design minimizes crosstalk and ensures high signal quality, especially in environments with high electromagnetic interference. The connectors are made of
polycarbonate and feature gold-plated contacts, ensuring reliable electrical connection and high corrosion resistance. The
strain relief protection prevents damage to the connector contacts during insertion and ensures a mechanically stable connection.
Technology Explained Simply
The designation
Cat6A refers to a cable category designed for data transmission at up to 10 Gbit/s over 100 metres. The
S/FTP shielding means that each of the four conductor pairs is individually shielded with a metallic foil, and additionally, the entire cable is surrounded by a metallic braid. This protects the signals from external interference and prevents the signals themselves from causing interference. The
LSZH jacket (Low Smoke Zero Halogen) is particularly safe, as it does not release toxic gases when heated or during fire, only producing minimal smoke. The
500 MHz bandwidth is crucial for signal quality at high data rates. The
AWG 26 conductor gauge is a standard for patch cables of this class and ensures sufficient electrical conductivity.
Compatibility and Accessories
The cable is compatible with all devices using RJ45 connectors and supporting the standards
ISO/IEC 11801 Class Ea,
EN 50173-1, and
ANSI/TIA-568-C.2. It can be used in networks with
PoE (Power over Ethernet),
PoE+, and
PoE++, making it suitable for powering IP cameras, access points, or telephones via the network cable. As accessories, various cable ties and cable organizers are available, including Velcro tape, cable ties in different lengths, and a flexible spiral organizer, which assist in proper routing and securing of the cable in server rooms or at workstations.
Installation and Mounting
Installation is performed by simply inserting the RJ45 connectors into the corresponding sockets of the network devices. The connectors feature strain relief protection, ensuring a mechanically secure connection. The minimum bending radius is
60 mm, which must be considered during installation to avoid damaging the cable structure. The cable is intended for indoor use and can operate at temperatures from
-20 °C to +75 °C. Packaging is done in a
Synergy21 blister pack, which protects the cable from mechanical damage.
Advantages in Operation
The patch cable offers high signal quality and reliability due to the double shielding (S/FTP) and the use of gold-plated contacts. The halogen-free jacket increases safety when used in enclosed spaces. Support for PoE technologies expands application possibilities, especially in surveillance systems and wireless networks. The length of 2 metres is ideal for use at workstations, in server rooms, or for connecting devices in close proximity. Packaging in a blister pack ensures clean and damage-free storage and installation.