| Technical data |
| CAT | CAT6A |
| Sheath | LSZH (halogen-free) |
| Shielding | S-STP(S/FTP) pair foil shielded |
| Length | 0,5m |
| Colour | Red |
| Connector type | Long |
| Cable type | Round |
| AWG (single conductor size) | 26 |
| POE cable power | POE/POE+/POE++ |
| MHz | 500Mhz |
| Cable outer diameter mm | 6.20 |
The patch cable from the brand Synergy 21, manufacturer's number S216461, is a data cable of category
CAT6A with a bandwidth of
500 MHz, designed for use in modern network infrastructures. It features
S-STP (S/FTP) shielding, where each pair of conductors is protected by a foil shield and additionally by an overall metal braid shield. This construction ensures high resistance to interference and minimizes electromagnetic influence, which is particularly advantageous in environments with high electromagnetic noise. The cable is
halogen-free (LSZH), meaning that no toxic gases are released in case of fire, making it suitable for use in enclosed spaces and public buildings. The cable length is
0.5 meters, with an outer diameter of
6.20 mm. The individual conductor size corresponds to
26 AWG, ensuring sufficient conductivity for the intended application. The connectors at both ends are
RJ45 connectors with latch nose protection, providing a secure and stable connection. The connectors are equipped with a
long housing, which enhances mechanical stability and facilitates easier handling. The cable color is
red, aiding in better identification and assignment during installation.
Applications
This patch cable is designed for use in professional networks, particularly in environments requiring high data rates and reliability. It is suitable for use in server rooms, data centers, office and industrial facilities, as well as in building cabling. Category 6A enables data transmission rates up to 10 Gbit/s over distances of up to 100 meters, with the specified length of 0.5 meters being optimized for short connections between switches, routers, network devices, or end devices. The support for
PoE, PoE+, and PoE++ also makes the cable suitable for powering IP cameras, access points, telephones, and other PoE-enabled devices, with power supplied via the network cable.
Functions and Equipment in Detail
The cable shielding follows the
S-STP (S/FTP) principle, where each pair of conductors is individually shielded with a metallic foil, and additionally, an overall shield made of metal braid surrounds the entire cable core. This double shielding reduces electromagnetic interference (EMI) and crosstalk between conductor pairs, enhancing signal quality and transmission stability. The use of
LSZH jacket material ensures low smoke emission and the release of non-toxic gases in case of fire, increasing safety in indoor environments. The connectors are equipped with
latch nose protection, ensuring mechanical stabilization and a secure connection. The connectors are made of
polycarbonate, providing high mechanical strength and resistance to breakage. The contacts are gold-plated, ensuring high corrosion resistance and reliable electrical conductivity.
Technology Explained Simply
Category 6A (Cat6A) is an extension of the Cat6 standard and enables a bandwidth of up to 500 MHz, which is necessary for high-speed data transmission. Shielding according to S-STP (S/FTP) means that each pair of conductors is individually shielded, and additionally, an overall shield surrounds the entire cable core. This protects signals from external interference and prevents the signals themselves from causing interference. The use of LSZH material (Low Smoke Zero Halogen) means that the cable does not release toxic halogens in case of fire, increasing safety. PoE support (Power over Ethernet) allows power and data to be transmitted over a single cable, simplifying installation and reducing the number of cables.
Compatibility and Accessories
The patch cable is compatible with all devices supporting RJ45 connectors and the standards
ISO/IEC 11801 Class Ea Channel Link,
EN 50173-1, and
ANSI/TIA-568-C.2. It can be combined with various accessories, such as
cable ties (e.g., 48,3 cm ( 19 inch ) accessory cable ties, L160 x W2.6 mm, pack of 100, transparent) or
cable organizers (e.g., flexible spiral organizer, 9–65 mm, 10 m, black), to ensure proper cabling and improved cable routing. The use of cable ties and organizers helps secure, organize, and protect the cable from mechanical stress.
Installation and Mounting
The installation of the patch cable is done by simply plugging the RJ45 connectors into the corresponding sockets of the network devices. The connectors feature latch nose protection, ensuring a secure connection. The cable length of 0.5 meters is suitable for short connections between devices in a rack or in close proximity. The minimum bending radius is
60 mm, which must be considered during installation to avoid damaging the cable. The operating temperature of the cable ranges from
-20 °C to +75 °C, allowing use in a wide range of environments.
Operational Advantages
The patch cable offers high signal quality and reliability due to the double shielding (S-STP) and the use of LSZH material. Support for PoE, PoE+, and PoE++ enables flexible and efficient power supply for network devices. The robust construction with gold-plated contacts and polycarbonate connectors ensures long service life and high mechanical stability. The red color facilitates identification and assignment in the network. The cable is packaged in a
Synergy21 blister pack, protecting the cable from damage and enabling clean presentation. The cables are
100 % electrically tested, ensuring the quality and reliability of the product.