| Technical data |
| CAT | CAT6A |
| Sheath | LSZH (halogen-free) |
| Shielding | S-STP(S/FTP) pair foil shielded |
| Colour | Grey |
| Length | 20m |
| Connector type | Long |
| Cable type | Round |
| AWG (single conductor size) | 26 |
| POE cable power | POE/POE+/POE++ |
| MHz | 500Mhz |
| Cable outer diameter mm | 6.20 |
The patch cable from the brand Synergy 21, manufacturer's number S216410, is a data cable of category
Cat6A with a bandwidth of 500 MHz. It is designed for use in modern network infrastructures, particularly in environments requiring high data rates and reliable signal transmission. The cable features
S-STP (S/FTP) shielding, where each pair of conductors is protected by a foil shield and additionally by an overall metal braid shield, minimizing electromagnetic interference. The shielding ensures high immunity against EMI (Electromagnetic Interference) and RFI (Radio Frequency Interference), which is particularly advantageous in industrial or densely populated IT environments.
Applications
The cable is suitable for use in structured cabling systems, particularly in office buildings, server rooms, data centers, and other environments where a stable and high-performance network connection is required. The Cat6A category enables data transmission rates up to 10 Gbit/s over a distance of up to 100 meters in channel mode according to ISO/IEC 11801 Class Ea. Use in combination with PoE (Power over Ethernet) is possible, as the cable meets the specifications for
PoE, PoE+ and PoE++. This makes it suitable for powering IP cameras, access points, telephones, and other PoE-enabled devices via the network cable.
Functions and Equipment in Detail
The cable is equipped with
RJ45 connectors at both ends, featuring a latch nose protection to ensure a secure and stable connection. The connectors are fitted with long housing (long body), which provides better mechanical stability and easier installation in patch panels or switches. The contact pins are gold-plated, ensuring high conductivity and corrosion resistance. The cable color is
grey, providing good visibility in cable ducts and rack systems without being obtrusive.
Technology Explained Simply
The
S/FTP shielding (Separate Foil Twisted Pair) means that each of the four conductor pairs is individually shielded with a metallic foil, and additionally the entire cable is surrounded by a metallic braid. This double shielding ensures particularly high resistance to interference and minimizes crosstalk, especially at high frequencies. The
AWG26 conductor gauge (26 American Wire Gauge) corresponds to a diameter of approximately 0.4 mm and is standard for Cat6A category. The cable has an
outer diameter of 6.2 mm, enabling a compact design without compromising mechanical stability. The jacket materials are
LSZH (Low Smoke Zero Halogen), meaning that in case of fire, only minimal smoke and no toxic halogen compounds are released – an important property for use in enclosed spaces and public buildings.
Compatibility and Accessories
The cable is compatible with all devices supporting the standards
ISO/IEC 11801 Class Ea,
EN 50173-1, and
ANSI/TIA-568-C.2. It can be used in combination with patch panels, switches, routers, and other network devices. As accessories, various cable ties, hook-and-loop tape, and cable organizers are available, aiding in proper cabling and management of cable bundles in rack systems. Cable ties in various lengths and widths, as well as the flexible cable organizer spiral band, enable structured and neat cabling.
Installation and Mounting
Installation is carried out by simply plugging the RJ45 connectors into the corresponding sockets of network devices. The long connector housings facilitate installation in tight racks and patch panels. The minimum bending radius is 60 mm, allowing flexible routing even in tight curves. Cable installation should be performed in a way that avoids mechanical stress, such as pressure or tension, to preserve the cable's lifespan and performance.
Operational Advantages
The cable offers high reliability and performance in networks with demanding requirements. The combination of S/FTP shielding, LSZH jacket, and PoE support makes it a versatile solution for modern IT infrastructures. 100% electrical testing (Open/Short/Miss Wire) and Fluke test compliance with ISO/IEC 11801 Channel Class Ea guarantee consistent quality. The operating temperature range is between -20 °C and +75 °C, enabling broad applicability in various environments. The cable is delivered in a blister pack from Synergy 21, ensuring protection during transport and storage.
Batteries are not included in the delivery scope.