| Technical data |
| CAT | CAT6A |
| Sheath | LSZH (halogen-free) |
| Shielding | S-STP(S/FTP) pair foil shielded |
| Colour | Grey |
| Length | 1,5m |
| Connector type | Long |
| Cable type | Round |
| AWG (single conductor size) | 26 |
| POE cable power | POE/POE+/POE++ |
| MHz | 500Mhz |
| Cable outer diameter mm | 6.20 |
The patch cable from the brand Synergy 21, manufacturer's number S216403, is a data cable of category
CAT6A with a bandwidth of
500 MHz, designed for use in modern network infrastructures. It features
S-STP (S/FTP) shielding, where each pair of conductors is individually shielded with foil and additionally an outer braid made of aluminium-magnesium (AL-MG) surrounds the entire cable. This construction ensures a high level of protection against electromagnetic interference and enables reliable data transmission even in critical environments. The cable is
grey and has a length of
1.5 metres. The connectors at both ends are
RJ45 connectors with latch nose protection, ensuring a secure and stable connection. The connectors are equipped with a
long housing, which provides better mechanical stability and easier handling during installation. The individual conductor gauge is
26 AWG, ensuring sufficient conductivity and mechanical strength. The cable is
halogen-free (LSZH), meaning low-smoke zero-halogen, which means it does not release toxic gases and produces minimal smoke when exposed to fire – an important feature for use in enclosed spaces and server rooms. The outer diameter is
6.20 mm, enabling a compact design without compromising mechanical robustness.
Applications
This patch cable is designed for use in professional networks, particularly in environments requiring high data rates and reliability. It is suitable for connecting switches, routers, network devices, PCs, laptops, and other end devices in a local area network (LAN). Category 6A enables data transmission rates up to 10 Gbit/s over the specified length of 1.5 metres. The shielding and high bandwidth make it particularly suitable for applications with high interference, such as data centres, server rooms, or industrial environments.
Functions and Equipment in Detail
The
S/FTP shielding provides double shielding: each pair of conductors is wrapped in a metallic foil, and the entire cable is surrounded by a metallic braid. This minimizes electromagnetic interference (EMI) and crosstalk between conductors. The connectors are equipped with
latch nose protection, which enhances mechanical stability and protects the cable from damage when inserting into the socket. The
long connector housings facilitate installation, especially in tight racks or dense cabling. The
halogen-free jacket (LSZH) is flame-retardant and meets the requirements of standards IEC 60332-1-2 (flame retardancy), IEC 61034 (low smoke), and IEC 60754-2 (halogen-free), increasing safety during use.
Technology Explained Simply
The designation
CAT6A stands for Category 6A, a standard for network cables that allows a maximum bandwidth of 500 MHz and data rates up to 10 Gbit/s over 100 metres (with appropriate installation). This ensures high resistance to interference. The
AWG26 conductor gauge corresponds to a diameter of approximately 0.4 mm and provides sufficient conductivity for the intended applications.
PoE support (Power over Ethernet) enables power supply through the network cable, reducing the number of required power cables. The
halogen-free jacket (LSZH) is particularly important in enclosed spaces, as it does not release toxic gases when exposed to fire.
Compatibility and Accessories
The patch cable is compatible with all devices that support RJ45 connectors and the standards
ISO/IEC 11801 Class Ea Channel Link,
EN 50173-1, and
ANSI/TIA-568-C.2. It can be combined with various accessories to optimize cabling. These include, for example,
cable organizers,
spiral wraps,
cable ties, and
velcro straps, which assist in proper routing and securing of cables. These accessories are also available in our range and support structured and neat cabling, especially in 48,3 cm ( 19 inch ) racks or server rooms.
Installation and Mounting
Installation is performed by simply inserting the RJ45 connectors into the corresponding sockets of the network devices. The long connector housings facilitate insertion, especially in tight sockets or dense cabling. The minimum bending radius is
60 mm, allowing flexible handling without damaging the cable. Cabling should be done to avoid unnecessary bends or tension to maximize cable lifespan. The use of cable ties or velcro straps for securing is recommended to ensure proper routing.
Operational Advantages
The patch cable offers high reliability and stability in data transmission, supports high data rates, and is suitable for use in demanding environments. The shielding ensures minimal interference, the halogen-free jacket increases safety, and PoE support reduces the number of required power cables. The cable is packaged in a
blister pack by Synergy 21, which protects the cable from damage and enables clean presentation. Each cable is
100 % electrically tested, guaranteeing high quality and reliability. The operating temperature range is between
-20 °C and +75 °C, enabling broad usability in various environments.