| Technical data |
| Sheath | LSZH (halogen-free) |
| Shielding | S-STP(S/FTP) pair foil shielded |
| Length | 0,5m |
| Colour | Blue |
| MHz | 250Mhz |
| CAT | CAT6 |
| Connector type | Long |
| Cable type | Round |
| Cable outer diameter mm | 5.80 |
| AWG (single conductor size) | 27 |
| POE cable power | POE/POE+/POE++ |
The patch cable from the brand Synergy 21, manufacturer's number S216009, is a data cable of category 6 (Cat6) with a length of 0.5 metres. It is designed for use in network infrastructures, particularly in environments where high data transfer rates and reliable signal transmission are required. The cable features S-STP (S/FTP) shielding, meaning each pair of conductors is individually shielded with foil shielding, and additionally, an outer braid protects the entire cable. This construction ensures high immunity against electromagnetic interference (EMI) and minimizes crosstalk between conductors. The shielding is especially important in environments with high electromagnetic noise, such as server rooms or industrial facilities.
Applications
This patch cable is suitable for use in local area networks (LAN), particularly in structures requiring high bandwidth and low latency. It is typically used between network devices such as switches, routers, PCs, or servers. The cable length of 0.5 metres makes it ideal for short connections within rack systems or near network outlet sockets. The blue colour supports visual identification and categorization of cables in complex network infrastructures.
Functions and Equipment in Detail
The cable is fitted with RJ45 connectors at both ends, which are equipped with a latch nose protection. This protection prevents the connector from accidentally disengaging from the socket and increases the mechanical stability of the connection. The connectors are designed for use in 8P8C sockets, which is the standard connection in Ethernet networks. The conductor gauge is 27 AWG, providing sufficient conductivity for data and power (PoE) transmission. The cable construction is round and has an outer diameter of 5.8 mm, enabling flexible handling and installation.
Technology Explained Simply
The S-STP (S/FTP) shielding technology combines the benefits of pair foil shielding (for each conductor pair) with an outer metal braid. This provides a double layer of protection against electromagnetic interference. The frequency bandwidth is 250 MHz, meeting the requirements of category 6 and enabling data transfer rates of up to 10 Gbit/s over short distances. The cable is suitable for PoE (Power over Ethernet), PoE+, and PoE++, meaning it can transmit power for network devices such as IP cameras, access points, or telephone systems via the network cable. Power supply occurs through the cable itself, eliminating the need for additional power supply lines.
Compatibility and Accessories
The patch cable complies with standards ISO/IEC 11801, EN50173-1, and ANSI/TIA-568-C.2, ensuring compatibility with standard network devices and infrastructures. It is designed for indoor use, with an operating temperature range of -20 °C to +75 °C, enabling broad application. As accessories, various cable management products are available, such as cable ties, hook-and-loop tape, and spiral organizers, which assist in proper routing and securing of cables in rack systems. These products support the structuring and maintenance of network infrastructures.
Installation and Mounting
Installation is performed by simply inserting the RJ45 connectors into the corresponding sockets of the network devices. The connectors are equipped with a latch nose protection, ensuring a secure connection. The cable length of 0.5 metres requires no special mounting tools, as the connection is typically made within a rack or in close proximity. The flexible construction of the cable facilitates bending and positioning, with a minimum bending radius of 60 mm to be observed to avoid cable damage.
Operational Advantages
The patch cable provides reliable and stable data transmission with high bandwidth. The S-STP shielding ensures minimal signal interference, which is particularly beneficial in environments with high electromagnetic noise. Support for PoE technologies reduces the number of required power cables and simplifies the installation of network devices. The halogen-free (LSZH) cable jacket material produces low smoke and toxicity during fire, increasing safety in enclosed spaces. Packaging is done in a PE bag with label, protecting transport and storage.