| General |
| Construction type | JBOD 2U |
| Drive bays | 24 piece |
| Drive format | 3.5 inch |
| Drive type | SAS/SATA |
| Data rate | 12 Gb/s |
| Backplane type | Single Expander |
| Connections | 4 Mini-SAS HD |
| Current supply | (1+1) redundant |
| Power supply efficiency | Titanium Level |
| Power supply control | PMBus |
| Cooling | 5x 8cm hot-swap fans |
| Remote control | IPMI |
| Compatible HBA/controllers | AOC-SAS3-9500-8E, AOC-SAS3-9500-16E, AOC-SAS3-9580-8I8E |
The Supermicro CSE-826SE1C-R1K02JBOD is a 2U JBOD enclosure for use in server and storage environments. It serves as a high-density storage chassis supporting up to 24 hot-swap drives in 3.5-inch format. The drives are arranged in two rows: 12 at the front and 12 in the middle position of the enclosure. The system is designed for SAS and SATA drives supporting a data transfer rate of 12 Gb/s. The backplane boards are designed as single expanders to ensure maximum bandwidth for the connected hard drives.
Applications
The enclosure is designed for applications requiring high storage density and flexible integration into existing server infrastructures. It is particularly suitable for data centers, backup systems, and high-performance computing applications where scalable storage expansion is needed without additional server hardware. The hot-swap function allows drives to be replaced during operation, increasing availability and maintainability.
Features and Equipment in Detail
The chassis features four Mini-SAS HD connectors, enabling both internal and external cascading. This allows multiple JBOD systems to be connected into a larger storage pool. Power supply is provided by two redundant, highly efficient power supplies of Titanium class, featuring PMBus control. This configuration ensures high energy efficiency and reliability, as in the event of a failure of one power supply, the other takes over the full load. Cooling is optimized by five 8-cm hot-swap fans, also redundantly designed, ensuring continuous cooling even if one fan fails.
Technology Explained Simply
The integrated JBOD Power Control Board supports IPMI (Intelligent Platform Management Interface), enabling remote monitoring and control of the enclosure over the network. This includes remote control of power-on and power-off processes, as well as monitoring of system states such as temperature, power consumption, and fan speed. Internal connection cables are included in the delivery scope, simplifying installation. The backplane boards support SAS/SATA drives with 12 Gb/s, ensuring fast data transfer and minimizing latency.
Compatibility and Accessories
The system is compatible with specific SAS host bus adapters (HBA) and controllers offered by Supermicro. These include the models AOC-SAS3-9500-8E (12 Gb/s, 2 external ports, SAS3 HBA), AOC-SAS3-9500-16E (12 Gb/s, 4 external ports, SAS3 HBA), and AOC-SAS3-9580-8I8E (12 Gb/s, 2 external ports, SAS3 RAID controller). These components enable integration of the JBOD into existing storage architectures and offer various configuration options depending on requirements for RAID functions or number of external connections.
Mounting and Installation
Installation is carried out in a standard 19-inch rack. The hot-swap drives can be inserted and removed without tools, simplifying maintenance. The IPMI functionality requires a network connection to enable remote control and monitoring.
Operational Advantages
The combination of redundant power supplies, redundant fans, and hot-swap drives increases system availability. IPMI control enables centralized monitoring and remote maintenance, reducing operational costs. The high storage density of 24 drives in 2U rack height makes the system particularly cost-effective for applications requiring large storage capacity in limited rack space. Support for 12 Gb/s SAS/SATA drives ensures high data transfer performance, sufficient for demanding applications.