| General |
| Power at high overload | 0,75 kW |
| Power at low overload | 1,1 kW |
| Operating voltage | 380-480 V |
| Voltage tolerance | +10/-10 % |
| Frequency range | 47-63 Hz |
| Ambient temperature high overload | -10 to +50 °C |
| Ambient temperature low overload | -10 to +40 °C |
| Degree of protection | IP20 |
| Construction size | FSA |
| Braking chopper | Integrated |
| Line filter | Class A |
| Overload duration 200% | 3 S |
| Overload duration 150% | 57 S |
| Overload duration 100% | 240 S |
| Compatible Control Units | CU230-2, CU240x-2, CU250S-2 |
| Firmware default | ab V4.6 |
| Max. pipe length | 450 m |
The Siemens SINAMICS Power Module PM240-2, type 6SL3210-1PE13-2AL1, is a power section for the modular frequency converter SINAMICS G120. It serves as a base for drive systems in machine building and, in combination with a control unit and an operator panel, forms a fully functional frequency converter. The module is designed for installation in enclosures and features an integrated Class A filter as well as a brake chopper, enabling four-quadrant applications. The size FSA and protection rating IP20 make it suitable for standard applications in industrial environments.
Applications
The Power Module PM240-2 is intended for a wide range of applications in general machine building, particularly in systems requiring flexible and reliable drive control. It is designed for use in enclosures and is suitable for drives with a rated power from 0.55 kW to 250 kW. The voltage variants include 200 V, 400 V, and 690 V, with this module designed for the range 3AC 380–480 V ±10 %. The operating voltage range is 47 to 63 Hz. The ambient temperature for high overload is -10 to +50 °C, and for low overload, -10 to +40 °C.
Functions and Equipment in Detail
The module features an integrated brake chopper, enabling reverse energy output in four-quadrant applications. The integrated Class A filter reduces electromagnetic interference and ensures EMC-compliant operation. The overload capacity is 0.75 kW at 200 % load for 3 seconds, 150 % load for 57 seconds, and 100 % load for 240 seconds. For low overload, the capacity is 1.1 kW at 150 % load for 3 seconds, 110 % load for 57 seconds, and 100 % load for 240 seconds. Dimensions are 196 mm (height) × 73 mm (width) × 165 mm (depth).
Technology Explained Simply
The frequency converter consists of several modules: the power section (here PM240-2), a control unit, and an operator panel. The PM240-2 handles electrical power conversion and is designed for operation in enclosures. The integrated Class A filter ensures low electromagnetic compatibility (EMC) and reduces network interference. The brake chopper enables the return of braking energy to the network, which is important for drives with frequent braking operations. The protection rating IP20 protects against finger contact and solid foreign objects, but is not waterproof.
Compatibility and Accessories
The Power Module PM240-2 can be combined with various control units, including CU230-2, CU240x-2, and CU250S-2, to form a complete frequency converter. Combination with a control unit is required to operate the module. Accessories include line reactors, sine filters, brake resistors, and operator units such as BOP-2 or IOP-2. Size FSA is released from firmware version V4.6 of the control unit. For EMC-compliant wiring, shielded plates and shielded connection kits are available.
Mounting and Installation
The module is designed as an installation unit for enclosures. Mounting is done into the enclosure, taking into account the dimensions 196 × 73 × 165 mm. Wiring is done via the designated connection terminals. A push-through variant is available for optimal heat dissipation outside the enclosure. The maximum cable length is up to 450 meters for sizes FSF and FSG, made possible by the robust design.
Advantages in Operation
The module offers high operational reliability through the integrated brake chopper and Class A filter. The modular design allows flexible adaptation to different requirements. Combination with various control units enables integration of safety functions such as STO, SS1, SBC, SLS, SDI, or SSM. The operating temperature ranges and overload capability ensure reliable performance under industrial conditions. The EMC-compliant design reduces interference during plant operation.