| General |
| Number of poles | 4 |
| Protection type | AC |
| Nominal current | 40 A |
| Earth fault trip current | 300 mA |
| Operating voltage | 400 V |
| N-conductor position | Left |
| Switch-off time | 40 ms |
| Cable grip and touch protection | included as standard |
| Actuation | slider manual operation |
The Siemens residual current circuit breaker type 5SV4644-0KL is a 4-pole RCD of the SENTRON series, designed for the protection of persons and property against electric shock. It is designed for use in electrical installations where a safe tripping operation is required in the event of fault currents. The device complies with DIN VDE regulations and provides protection against electric shock by rapidly disconnecting dangerous earth fault currents. It is specifically designed for applications with sinusoidal alternating fault currents (Type AC), making it suitable for many standard applications in buildings and industrial facilities.
Applications
The RCD is used in electrical distributions to trip within a maximum of 40 ms at a fault current of 300 mA. This protects persons from life-threatening electric shocks and prevents fires that may be caused by electrically ignited fault currents. The device is installed in distribution enclosures, mounted on a DIN rail. The N conductor is positioned on the left, which is important for correct integration into the electrical installation. The devices are not permitted in all countries; national installation regulations must be observed.
Functions and Equipment in Detail
The circuit breaker features an integrated standard shroud and shock protection, enabling safe mounting and maintenance. Operation is via a slider-hand actuation, allowing the device to be removed from the DIN rail without tools. This significantly simplifies installation and maintenance. On the front of the device, a data matrix code is located, which allows technical information to be quickly and easily accessed via the Siemens Industry Online Support App.
Technology Explained Simply
The circuit breaker is rated for a nominal current of 40 A and trips at a fault current of 300 mA. The operating voltage is 400 V AC. The protection type is AC, meaning it is suitable for sinusoidal alternating fault currents. The 4-pole configuration enables protection of all conductors, including the N conductor, which is positioned on the left. The fast tripping time of up to 40 ms ensures effective protection against electrical hazards.
Compatibility and Accessories
The RCD can be extended with various accessories from the Siemens system building kit. These include, for example, pin busbars, auxiliary power switches, fault signal switches, load current release units, under-voltage release units, remote actuators, and intermediate frames for N-distributors. These components allow adaptation to specific requirements, such as integration into larger switchgear installations or expansion with auxiliary functions.
Mounting and Installation
Mounting is carried out on a DIN rail in the distribution enclosure. The tool-free release function via the slider-hand actuation simplifies installation and removal. The positioning of the N conductor on the left must be observed during installation to ensure correct operation. The devices are intended for use in enclosed distribution enclosures.
Advantages in Operation
The circuit breaker provides reliable and fast protection against electrical hazards. The integrated safety features such as shroud and shock protection, as well as tool-free mounting, increase safety and efficiency during installation. The data matrix code function enables quick access to technical data, simplifying maintenance and documentation. Compatibility with the Siemens system building kit allows flexible expansion of functions according to requirements.