Further information for Siemens 5SV3646-6 RCD 63/0.3A
General
Degree of protection
Type A
Number of poles
4
Nominal current
63 A
Rated residual current
300 mA
Operating voltage
400 V AC
Built-in width
4 TE
Protection function
residual current protection
System
SENTRON
Actuation
slider manual operation
Data matrix code
The Siemens residual current circuit breaker type 5SV3646-6 is a 4-pole RCD of the SENTRON series, designed for the protection of persons and property against electric shock. It features a rated current of 63 A and a rated residual current of 300 mA, with an operating voltage of AC 400 V. The switch is designed as type A, meaning it can detect both alternating and direct current residual currents, making it particularly suitable for applications with electronic devices or power electronics. The mounting width is 4 TE, enabling installation in standard installation enclosures.
Applications
The residual current circuit breaker is used in electrical installations to automatically disconnect the circuit when a residual current of 300 mA or more is detected. It is intended for use in residential, commercial, and industrial installations, particularly where high safety requirements exist. The 4-pole design enables protection of all conductors, including the neutral conductor, which is required in installations with neutral conductor connections. Type A is particularly suitable when devices with direct current components (e.g. LED lighting, electronic controls) are present in the circuit.
Functions and equipment in detail
The switch features an integrated encircling and shock protection, ensuring safe handling and minimizing the risk of accidents during installation or maintenance. The slider-hand operation allows tool-free removal of the device from the DIN rail or from the busbar system, simplifying installation and maintenance. A data matrix code on the device provides access to technical data via the Siemens Industry Online Support app, supporting documentation and maintenance.
Technology explained simply
The circuit breaker operates on the principle of residual current protection: it monitors the current flow in all conductors and trips when an imbalance between incoming and outgoing current is detected, indicating a residual current. The type A design enables detection of pulsating direct current residual currents, which can occur in modern electronic devices. The rated voltage of 400 V AC is designed for standard low-voltage installations in Europe. The rated current of 63 A is suitable for medium to high loads, as found in apartments, offices, or production facilities.
Compatibility and accessories
The switch is part of the SENTRON system and can be extended with various accessories available in the system kit. These include, for example, auxiliary switches, fault signal switches, pin busbars in various designs (e.g. 10 mm² or 16 mm², 3-phase or 4-pole), end plates, terminal covers, and remote actuators. These components enable flexible adaptation to specific installation requirements, such as signal integration or expansion of connection capacity.
Mounting and installation
The switch is mounted on a DIN rail, with the slider-hand operation enabling tool-free insertion and removal. Installation takes place in an electrical enclosure or distribution board, taking into account the mounting width of 4 TE. Connections are made via the integrated terminals, designed for connection to cables. Installation must comply with applicable regulations and standards, particularly VDE 0100 and DIN VDE 0664.
Advantages in operation
The circuit breaker provides reliable protection against electric shock and damage caused by residual currents. Tool-free mounting and maintenance reduce work effort. Integration into the SENTRON system enables modular expansion of functions, allowing the installation to be adapted to future requirements. The availability of technical data via the data matrix code supports maintenance and documentation.