Siemens 5SU13566KK16, EAN: 4001869306728

Siemens 5SU13566KK16 RCD Switch 1+N-pole 30mA

Installation > Modular devices / equipment installation > RCD

Siemens 5SU13566KK16 RCD Switch 1+N-pole 30mA

Lieske Part No. 487666
Mfg Part No 5SU13566KK16
EAN-Code 4001869306728
Manufacturer Siemens
Here only 137,70 EUR
163,86 EUR incl. VAT

Further information for Siemens 5SU13566KK16 RCD Switch 1+N-pole 30mA

General
Degree of protectionType A
Earth leakage tripping30 mA
Nominal current16 A
Switching power6 kA
Nominal voltage230 V AC
CharacteristicB-Char
Poles1P+N
Width of module70 mm
CertificationDIN EN 61009-1, DIN EN 61009-2-1
Terminal typeDouble chamber terminals
Accessory compatibilityPin busbars 5ST3, remote actuators, auxiliary switches, interlock devices
The Siemens FI/LS switch type 5SU1356-6KK16 is a combined protective switch for use in electrical distributions. It provides simultaneous protection against overload, short circuit, and fault currents and is part of the SENTRON series. The device is designed for installation in row or distribution cabinets and features a 1P+N wiring configuration, meaning it protects both the live (L) and neutral (N) conductors. The Type A protection class enables detection of pulsating fault currents, which may occur in devices with electronic control. The rated current is 16 A, and the switch is designed for a rated voltage of 230 V AC. The fault current tripping occurs at a value of 30 mA, which corresponds to the standard for personal protection in residential and commercial buildings. The switching capacity is 6 kA, indicating the device's ability to safely interrupt a short circuit.

Residual current circuit breaker with integrated line protection (FI/LS) combines two functions in one device, simplifying installation and enhancing safety. The device is tested and certified according to DIN EN 61009-1 and DIN EN 61009-2-1, confirming compliance with European safety standards for residual current circuit breakers. The B-characteristic (B-Char) ensures selective tripping during overloads, with the switch responding slowly at current values starting at approximately 1.1 times the rated current (In) and tripping faster at higher values. This is particularly important to avoid unnecessary tripping during short-term current surges, such as those occurring with motors or heating appliances.

Double-chamber terminals allow for easy and secure connection of conductors with different cross-sections. This simplifies installation and ensures a reliable electrical connection. The terminals are designed to maintain a stable contact even with different wire diameters. Connection to other SENTRON protective switches is achieved via pin busbars of the 5ST3 series, enabling quick and secure parallel connections. This is particularly advantageous when installing multiple switches in a distribution board.

Accessories and expansion options are diverse. The device can be supplemented with various add-on components such as load switches, auxiliary switches, remote actuators, or lockout devices. For example, a load switch (5ST3030) can extend the switch's functionality to automatically operate under specific operating conditions. An auxiliary switch (5ST3062) enables signaling functions, e.g., to indicate the switch status. Remote actuators such as the 5ST3073-0MC allow remote control, which is useful in industrial applications. Compatibility with the Siemens system building kit ensures modular expandability.

Installation is carried out in standard distribution cabinets with a module width of 70 mm (D=70 mm). The devices are suitable for installation in N-distribution boards, and the use of intermediate frames such as the 8GB4561 SIMBOX 63 facilitates integration into existing systems. The surface of the switch is marked with a Data Matrix code, from which technical data can be retrieved via the Siemens Industry Online Support app. This supports maintenance and documentation during operation.

Operational safety is ensured by the combination of residual current and overload protection. The switches respond to fault currents starting at 30 mA, protecting against electrical accidents. At the same time, the B-characteristic prevents overloading of the conductors. The switching capacity of 6 kA ensures safe interruption during short circuits, thereby preventing damage to the installation and fire hazards. The devices are suitable for use in residential, commercial, and industrial installations, particularly where high safety and reliability are required.

Compatibility with other SENTRON products and accessories from the Siemens system building kit enables flexible and expandable installation. The use of pin busbars (e.g., 5ST3608, 5ST3606) or CU busbars (5ST3706) facilitates the connection of multiple switches. Combining with auxiliary switches, remote actuators, or lockout devices extends functionality according to the application. The devices are designed for use in distribution boards with standard module dimensions, supporting integration into existing systems.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/487666
qrcode für Siemens 5SU13566KK16 RCD Switch 1+N-pole 30mA