Siemens 5SU11547KK13, EAN: 4001869307527

Siemens 5SU1154-7KK13 FI circuit breaker 1+N-pole 13A

Installation > Modular devices / equipment installation > RCD

Siemens 5SU1154-7KK13 FI circuit breaker 1+N-pole 13A

Lieske Part No. 299793
Mfg Part No 5SU11547KK13
EAN-Code 4001869307527
Manufacturer Siemens
Here only 187,20 EUR
222,77 EUR incl. VAT

Further information for Siemens 5SU1154-7KK13 FI circuit breaker 1+N-pole 13A

General
Degree of protectionEarth leakage circuit breaker
Rated residual current10 mA
Switching power10 kA
Nominal voltage230 V AC
Nominal current13 A
CharacteristicC
Number of poles1P+N
CertificationDIN EN 61009-1, DIN EN 61009-2-1
Terminal typeDouble chamber terminals
System compatibilitySENTRON, pin busbars 5ST3
Data matrix codeYes
The Siemens FI/LS switch type 5SU1154-7KK13 is a combined protection switch for use in electrical installations, providing protection against overload, short circuit, and fault currents simultaneously. It belongs to the SENTRON series and is designed as a 1P+N model, where 1P+N indicates a single-pole main conductor plus neutral conductor. The switch is rated for a nominal voltage of 230 V AC and features a nominal current of 13 A with C-characteristic, making it suitable for applications with medium to high inrush currents. The fault current tripping occurs at a nominal fault current of 10 mA, and the switch is type A, meaning it can also detect pulsating fault currents. The switching capacity is 10 kA, indicating high short-circuit resistance and suitability for use in residential and commercial electrical installations.

Residual current circuit breaker with integrated line protection offers a compact solution that replaces the need for separate FI and LS switches. The devices are VDE-tested and certified according to DIN EN 61009-1 and DIN EN 61009-2-1, confirming compliance with European safety standards for residual current circuit breakers. The double-chamber terminals allow for easy connection of conductors with different cross-sections, simplifying installation in various scenarios.

Applications include primarily protection functions in residential and commercial buildings, where high safety against electrical hazards is required. The switch is designed for use in individual installations as well as in distributions with multiple protection switches. Its compatibility with pin busbars of type 5ST3 enables quick and secure connections between devices when used in combination with other SENTRON devices.

Functions and equipment in detail include integrated fault current detection with a nominal fault current of 10 mA and type A, which also detects pulsating fault currents. The C-characteristic ensures sufficient tripping delay for transient loads, such as those occurring with motors or electronic devices. The switching capacity of 10 kA ensures safe disconnection even under high short-circuit currents. The switch is marked with a data matrix code, allowing technical data to be retrieved via the Siemens Industry Online Support app.

Technology explained simply shows that the FI/LS switch functions as an RCBO (Residual Current Breaker with Overcurrent Protection). It combines the functions of a line protection switch (LS) and a residual current circuit breaker (FI) in a single device. The double-chamber terminals allow for securing conductors of different cross-sections, increasing installation flexibility. The protection functions are secured by certification according to DIN EN 61009-1 and -2-1, ensuring electrical safety and reliability.

Compatibility and accessories include use with pin busbars of type 5ST3, enabling quick and secure connections between multiple SENTRON devices. Additionally, various accessories such as auxiliary switches, remote actuators, load current tripping units, under-voltage tripping units, lockout devices, pin busbars in various versions, and wall enclosures can be used to adapt the switch’s functionality to specific requirements. The mentioned accessories are intended for extending functions such as remote control, signaling, or additional protection features.

Mounting and installation is carried out in standard distribution enclosures or boxes. The double-chamber terminals simplify the connection of conductors with different cross-sections, reducing installation time. The devices are designed for an installation height of 70 mm, enabling integration into standard distribution systems. The use of pin busbars 5ST3 allows parallel connection of multiple switches, making installation in larger systems more efficient.

Operational advantages lie in the combination of two protection functions in a single device, saving space and simplifying installation. The high switching capacity of 10 kA and C-characteristic ensure reliable disconnection in case of overload and short circuit. Type A detection of fault currents increases safety, especially with devices featuring electronic circuits. Certification according to DIN EN 61009-1 and -2-1 ensures compliance with safety standards. Integration into the SENTRON system allows flexible expansion of functions through accessories. Batteries are not included in the delivery scope.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/299793
qrcode für Siemens 5SU1154-7KK13 FI circuit breaker 1+N-pole 13A