| General |
| Degree of protection | Type A |
| Number of poles | 4 |
| Nominal current | 40 A |
| Earth fault trip current | 30 mA |
| Operating voltage | 400 V |
| Tripping characteristic | Short-time delayed |
| Compatibility | for circuit breakers 5SY |
| Application | person, fire, and line protection |
The Siemens residual current circuit breaker 5SM2342-6KK01 is a
4-pole RCD block of type A, specifically designed for combination with circuit breakers of the 5SY series. It provides protection of electrical installations against
fault currents, particularly in the areas of
personnel protection,
fire protection, and
circuit protection. The combination is tool-free, achieved by simply plugging together, enabling quick and secure installation in enclosures or distributions. The RCD block is designed with short-time delay, supporting selective tripping in complex power supply networks to avoid unnecessary disconnections.
Applications
The RCD block 5SM2342-6KK01 is designed for use in electrical installations with a rated voltage of 400 V AC. It is particularly suitable for applications requiring high safety against electrical hazards, such as in residential buildings, commercial enterprises, industrial plants, or for supplying electrical devices with increased risk. The 4-pole configuration enables protection of 3-phase systems with neutral conductor, which is common in industrial and commercial electrical engineering. The type designation A makes it suitable for detecting pulsating fault currents, which may occur with devices featuring electronic power supplies or frequency converters.
Functions and Equipment in Detail
The RCD block features a rated current of 40 A and a fault current tripping threshold of 30 mA. These values are generally sufficient for personnel and installation protection, especially in installations executed according to VDE 0100-410 and similar standards. The short-time delayed tripping (type A) ensures that the switch does not immediately trip upon detection of a fault current, but introduces a brief delay to enable selective tripping. This is particularly important when multiple RCDs are installed in a hierarchy, ensuring that only the nearest RCD trips and not the upstream one.
Technology Explained Simply
The RCD block operates on the principle of differential current measurement: it monitors the current flow in the conductor cross-section and detects when the current flowing into the load does not fully return — an indication of a fault current flowing through an unintended path (e.g., through a person). Upon reaching the preset tripping threshold of 30 mA, the circuit is interrupted within the specified delay time. The 4-pole configuration ensures that all conductors (L1, L2, L3, N) are protected, which is required for safety in 3-phase systems. The operating voltage is 400 V AC, matching the standard voltage in industrial and commercial electrical engineering.
Compatibility and Accessories
The RCD block 5SM2342-6KK01 is specifically designed for combination with circuit breakers of the 5SY series. It can be plugged together tool-free with corresponding circuit breakers. Suitable accessories include, for example, the RCD block 5SM2842-8 (4-pole, type A, selective, 40 A, 1000 mA), adapters such as 5ST3820-3 for remote operation, as well as other RCD blocks like 5SM2642-6 or 5SM2342-0. These components extend application possibilities and allow individual configurations according to requirements. The accessories are designed to be retrofitted on the right side of the circuit breaker.
Installation and Mounting
Mounting is tool-free, achieved by simply plugging the RCD block onto the corresponding 5SY series circuit breaker. This significantly simplifies installation in enclosures and distributions. The combination is designed to be carried out without additional tools or mounting aids. Positioning occurs in modular installations, with dimensions and form factor aligned to standard sizes of the 5SY series.
Operational Advantages
Using the RCD block 5SM2342-6KK01 provides high safety through the combination of circuit protection and residual current protection in a single module. Tool-free mounting reduces installation time and minimizes error sources. The short-time delayed tripping enables selective disconnection, increasing the availability of the electrical installation. Compatibility with a wide range of circuit breakers and accessories offers flexibility in planning and implementing control systems.