| General |
| Number of poles | 2 |
| Earth fault type | A |
| Tripping characteristic | Short-time delayed |
| Nominal current | 63 A |
| Rated residual current | 30 mA |
| Operating voltage | 230 V AC |
| Compatibility | for circuit breakers 5SY |
The Siemens RCD block type 5SM2325-6KK01 is a 2-pole residual current circuit breaker, specifically designed for combination with circuit breakers of the 5SY series. It provides protection for electrical installations against personal injury, fire, and wiring damage by detecting and interrupting fault currents. The RCD block is of type A, meaning it can detect both alternating and rectifier fault currents, and features a short-time delayed tripping characteristic, enabling selective disconnection in complex circuits. The rated current is 63 A, and the rated residual current is 30 mA, making it suitable for use in residential and small commercial installations. The operating voltage is 230 V AC, which corresponds to the standard voltage in household and small-scale applications.
Residual current circuit breakers are essential for safety in electrical installations, as they trip within milliseconds at a fault current of 30 mA to prevent electric shocks. The
short-time delayed tripping ensures that the RCD block does not trip at every minor, transient fault current, but only at sustained or dangerous currents, thereby increasing the reliability and stability of the installation.
Applications include residential buildings, commercial and small industrial facilities where high safety requirements apply. The RCD block is particularly suitable for circuits requiring selective disconnection to maintain power supply to other parts of the installation when a fault occurs in a specific area. Combination with 5SY series circuit breakers is tool-free, achieved by simple plug-in, which simplifies installation and reduces error susceptibility. The modular design allows flexible adaptation to different requirements.
Functions and equipment in detail include tool-free mounting, ensuring quick and secure installation. The tripping characteristic is short-time delayed, meaning the breaker trips within a defined time window at a fault current of 30 mA to avoid unnecessary disconnections. The rated voltage of 230 V AC is designed for the standard mains voltage in Germany and Europe. The RCD block is designed for use in 2-pole circuits, ensuring protection for two conductors (e.g. live and neutral).
Technology explained simply shows that the RCD block contains an electronic monitoring mechanism that continuously monitors current flow in the conductors. If an imbalance is detected between the current entering the installation and the current leaving it, a fault current is assumed. At a difference of 30 mA, the breaker trips within milliseconds. The short-time delayed tripping means the breaker does not trip immediately, but after a brief delay, reducing the likelihood of false tripping due to transient disturbances.
Compatibility and accessories include use with circuit breakers of the 5SY series.
Mounting and installation is performed by simple plug-in with a compatible 5SY series circuit breaker. Mounting requires no tools, which speeds up installation and reduces error susceptibility. Positioning is done in an enclosure or distribution board, with electrical connections carried out in accordance with electrical engineering regulations.
Operational advantages lie in high safety through detection of fault currents that could cause electric shocks. The short-time delayed tripping prevents unnecessary disconnections, increasing the availability of the installation. Tool-free mounting reduces installation time and error probability. Compatibility with various circuit breakers enables flexible adaptation to different requirements.