| General |
| Degree of protection | B |
| Nominal voltage | 400 V |
| Nominal current | 6 A |
| Breaking capacity | 6 kA |
| Number of poles | 3 way |
| Construction type | rack mounting |
| Mounting method | tool-free |
| Busbar | rear-mounted |
The circuit breaker
5SL6306-6 from Siemens belongs to the SENTRON series and is designed for safe short-circuit and overload protection in standard applications in residential and commercial buildings. The device is 3-pole, has a rated voltage of 400 V and a rated current of 6 A. The tripping curve
B enables selective disconnection in case of overloads and short circuits, with a breaking capacity of 6 kA. The design is intended for modular installation in enclosures, where tool-free mounting and dismounting ensure quick installation and maintenance. The rear-mounted busbar facilitates wiring of the supply and ensures a structured and secure connection of the cables.
Applications
The switch is intended for use in electrical installations in residential and commercial buildings, where reliable protection of circuits against overload and short circuit is required. It is particularly suitable for applications where high operational safety and easy handling are prioritized, such as in distribution boards for lighting, heating, or small consumer installations. The 3-pole design makes it suitable for three-phase supply lines.
Functions and Equipment in Detail
The circuit breaker 5SL6306-6 offers integrated short-circuit and overload protection defined by the tripping curve B. This curve ensures that the switch disconnects within seconds when current exceeds 3 to 5 times the rated current (here 6 A), while lower overloads trigger a time-delayed disconnection. The breaking capacity of 6 kA ensures safe disconnection even at high short-circuit currents. Tool-free mounting allows for quick and secure installation without additional tools. The rear busbar reduces wiring time and improves clarity in the enclosure.
Technology Explained Simply
The tripping curve
B is a standard curve for circuit breakers, suitable for applications with low to medium inrush current, such as lighting, heating, or small motors. When the current rises above 3 to 5 times the rated current (here 6 A), the switch trips within seconds. The breaking capacity of 6 kA means the switch can safely disconnect even at high short-circuit currents without damage. The 3-pole design enables protection of three-phase circuits. The design is intended for installation in standard enclosures, with tool-free mounting enabling quick installation.
Compatibility and Accessories
The switch is part of the SENTRON series and can be extended with various accessories to integrate additional functions. Compatible accessories include auxiliary switches such as the 5ST3010 (1 NO + 1 NC) or the 5ST3062-0MC (auxiliary/fault signal switch), which can be used for signal transmission or status indication. Remote actuators such as the 5ST3073-0MC enable remote control of the switch. Pin busbars such as the 5ST3740-1 (3-phase, 58 TE, 1032 mm) or the 5ST3710 (1016 mm, 16 mm²) provide a secure and structured connection for cables. Combining with spacing elements such as the 5TG8240 (0.5 TE) allows flexible positioning in the enclosure. The lockout device 5ST3807 with hasp lock offers additional protection against unauthorized access.
Mounting and Installation
Mounting is tool-free in standard enclosures. The rear busbar enables simple and secure wiring of the supply. Installation is done by simply snapping the device into the designated holders. Wiring of the load side is done via the front terminals. Tool-free dismounting facilitates maintenance and replacement. The mounting width is 1 TE, enabling compact placement in the enclosure.
Advantages in Operation
The switch offers high operational safety through integrated short-circuit and overload protection. Tool-free mounting and dismounting reduce installation time and minimize the risk of mounting errors. The rear busbar ensures structured and secure wiring. Compatibility with a wide range of accessories allows flexible expansion of functions, such as remote control or status indication. The 3-pole design makes it suitable for three-phase installations, with tripping curve B being optimally suited for standard applications in residential and commercial buildings.