| General |
| Contact type | Changeover contacts |
| Contact spacing | 7 mm |
| Accessory for | 3VA1, 3VA20-26 SENTRON compact circuit breaker |
The tripped status indicator switch type 3VA9988-0AB13 from Siemens is an accessory for the SENTRON compact circuit breakers of the 3VA1 series as well as 3VA20 to 3VA26 series. It serves as a mechanical signal transmitter, providing the status of the circuit breaker—particularly the tripped state—via changeover contacts to external control or monitoring systems. The designation type HQ refers to the switch's construction, featuring a contact arrangement with a 7 mm contact spacing. The electronics-compatible design enables use in installations connected to electronic control or monitoring systems, with contacts suitable for actuating relays, indicator lights, or control devices.
Applications
The indicator switch is used in industrial electrical installations where monitoring the status of circuit breakers is required. It is particularly suitable for installations with high availability requirements, where immediate detection of a tripping event is necessary to trigger follow-up processes such as alarm signaling, emergency shutdown, or maintenance orders. Its use in combination with SENTRON circuit breakers from the 3VA series enables an integrated and uniform system solution, characterized by standardized interfaces and compatible accessories.
Functions and Equipment in Detail
The indicator switch features changeover contacts that change state when the switch is operated—for example, during tripping. This enables actuation of external devices that respond to the state change. The electronics-compatible design ensures compatible connection to electronic controls, with contacts designed for use in circuits with low loads. The type HQ contact arrangement with 7 mm spacing is designed for mounting on the designated circuit breakers of the 3VA series, ensuring a secure mechanical connection.
Technology Explained Simply
The function of the indicator switch is based on mechanical coupling with the main tripping mechanism of the circuit breaker. When the breaker trips, the indicator switch is actuated via a mechanical linkage, causing the changeover contacts to change state. This state change can be transmitted via a cable to a control device or indicator circuit. The electronics-compatible design means the contacts are suitable for use in circuits with low current and voltage levels, as commonly found in electronic controls.
Compatibility and Accessories
The indicator switch is specifically designed for SENTRON compact circuit breakers of types 3VA1 as well as 3VA20 to 3VA26. It is part of the unified 3VA system and can be directly mounted at the designated attachment points on the breakers. Compatibility with these breaker types ensures secure and reliable signal transmission.
Mounting and Installation
Mounting is performed directly on the circuit breaker, with the indicator switch attached to the designated connection points. The mechanical connection is made via the integrated actuating rod, which connects to the breaker’s tripping mechanism. Electrical connection of the contacts is made via the designated terminal clamps, designed for connection to external control lines. No additional tools or mounting aids are required, as the indicator switch is designed for direct mounting on 3VA series breakers.
a system. For all applications.
Advantages in Operation
Integration of the indicator switch into the 3VA system enables uniform and standardized status monitoring. The electronics-compatible design allows direct connection to modern control and monitoring systems, simplifying system integration. The reliability of mechanical signal transmission ensures fast and secure detection of tripping events, enhancing operational safety. Use in combination with SENTRON circuit breakers ensures high compatibility and ease of maintenance.