| General |
| Construction size | S00 |
| Trip class | 10 |
| A-trigger | 0,28...0,4 A |
| N-trigger | 5,2 A |
| Degree of protection | IP20 |
| Dielectric strength | 690 V |
| Overvoltage withstand | 6 kV |
| Operating voltage | 690 V |
| Operating frequency | 50...60 Hz |
| Operation temperature | -20...+60 °C |
| Storage and transport temperature | -50...+80 °C |
| Relative humidity | 10...95 % |
| Total power consumption | 5 W |
| Number of poles | 3 |
| Connection type | Screw connection |
| Mounting | On 35 mm DIN rail |
| Short-circuit withstand capability (Ics) | 100 kA |
| Maximum short-circuit current (Icu) | 100 kA |
| DC short-circuit current (Icn) | 10 kA |
| Approval | IEC, UL/CSA |
The Siemens power switch type 3RV2011-0EA10 belongs to size S00 and is specifically designed for motor protection. It features a CLASS 10 A-trip unit with an adjustable trip current of 0.28 to 0.4 A, as well as an N-trip unit with a rated value of 5.2 A. The switch provides safe disconnection in case of short circuit and protects consumers and systems from overload. It also enables safe isolation of the system from the network. The compact design and low heat generation make it particularly suitable for use in consumer branches, including drives with IE3 and IE4 efficiency classes. The SIRIUS 3RV2 series replaces the previous 3RV1 series and offers a unified system solution with modular construction.
Applications
The power switch is intended for use in industrial systems, particularly for protecting electric motors. It can be used in various applications, including motor protection, system protection, short-circuit protection for starter combinations, transformer protection, as a main or emergency stop switch, and in IT networks. The worldwide certification according to IEC and UL/CSA enables use in various markets. The devices are also suitable for applications in hazardous areas (ATEX or IEC Ex), with certification available upon request.
Functions and Equipment in Detail
The switch features a thermal overload trip unit that monitors load currents and trips the switch when the set value is exceeded. The trip characteristic corresponds to trip class 10. The mechanical life expectancy is typically 100,000 switching cycles, as is the electrical life expectancy. The operating voltage is 690 V, with the operating voltage for AC-3 up to 690 V. The operating frequency is designed for 50 to 60 Hz.
Technology Explained Simply
The switch is equipped with screw terminals, ensuring a secure and vibration-resistant connection. The insulation strength is 690 V at pollution degree 3. The overvoltage strength is 6 kV. The protection rating is IP20 at the front and at the terminals. The operating temperature ranges from -20 °C to +60 °C, with storage and transport temperature ranging from -50 °C to +80 °C. The relative humidity during operation is 10 to 95 %. The maximum installation height is 2000 m above sea level. The total power consumption is typically 5 W.
Compatibility and Accessories
The switch is designed for mounting on a 35 mm standard rail holder according to DIN EN 60715. It can be installed in any mounting position. Accessories include various auxiliary switches, such as horizontal or side-mounted models, as well as undervoltage trip units and connection modules. These are uniformly available for all sizes in the SIRIUS 3RV2 series. Combining it with the power supply system SIRIUS 3RV29 reduces main circuit wiring.
Mounting and Installation
Mounting is done via screw or spring-cage connection on a 35 mm DIN rail. Dimensions are 97 mm height, 45 mm width, and 96 mm depth. For side mounting, a clearance of 30 mm to conductive parts is required. Required clearances above and below are each 50 mm. Mounting is simple and does not require special tools.
Advantages in Operation
The switch is characterized by high operational reliability, low heat generation, and long service life. The modular design allows flexible expansion with accessories. The worldwide certification and suitability for hazardous areas extend the range of applications. The integrated protection function for overload and short circuit ensures reliable protection in industrial systems.