Siemens 3RV10111HA10, EAN: 4011209263680

Siemens 3RV1011-1HA10 motor protection switch S00 5.5-8.0 A

Industrial Material > Control devices / Pilot devices > Motor protection switch

Siemens 3RV1011-1HA10 motor protection switch S00 5.5-8.0 A

Lieske Part No. 768215
Mfg Part No 3RV10111HA10
EAN-Code 4011209263680
Manufacturer Siemens
Here only 105,91 EUR
126,03 EUR incl. VAT

Further information for Siemens 3RV1011-1HA10 motor protection switch S00 5.5-8.0 A

General
Construction sizeS00
Degree of protectionweatherproof
A-triggerCLASS 10
A-trip unit adjustment range5,5...8 A
N-trigger104 A
Connection typeScrew connection
Switching capacityStandard switching capacity
Application rangemotor protection, consumer branch, IT networks
ApprovalsIEC, UL/CSA, ATEX, IEC Ex
The Siemens motor protection circuit breaker type 3RV1011-1HA10 belongs to size S00 of the SIRIUS series and is specifically designed for motor protection. It provides safe disconnection in case of short circuit and protects consumers and systems against overload. Additionally, it enables safe isolation of the system from the power supply. The device is compact and weather-resistant, making it particularly suitable for use in consumer branch circuits, including applications with IE3 and IE4 motors. The low heat dissipation of the switch reduces thermal stress in the enclosure and supports efficient heat dissipation. Global approvals according to standards such as IEC and UL/CSA, as well as suitability for hazardous areas (ATEX or IEC Ex), extend its application range in various industrial environments.

Applications
The motor protection circuit breaker is intended for use in industrial systems, particularly in drive technology and machine building. It is used in consumer branch circuits where reliable protection against overload and short circuit is required. Application in IT networks is also possible, with device variants available for main and emergency stop switches. The weather-resistant design also makes the switch suitable for outdoor use, provided environmental conditions comply with specified standards.

Functions and Equipment in Detail
The switch features a CLASS 10 A tripping unit with an adjustable range of 5.5 to 8 A, optimized for motor protection. The N tripping unit has a rated current of 104 A and ensures disconnection in case of short circuit. The screw connection variant enables a secure and mechanically stable connection of the conductors. The device is equipped with standard switching capacity, ensuring reliability during switching operations. The integrated protection function safeguards the system against thermal overload and electrical disturbances.

Technology Explained Simply
The motor protection circuit breaker operates on the principle of thermal and magnetic tripping. The thermal tripping unit responds to sustained overload by simulating the heat development in the motor and opens the switch when the set current range is exceeded. The magnetic tripping unit reacts to sudden current surges, such as those occurring during short circuits, and disconnects within milliseconds. The combination of both tripping units ensures comprehensive protection. Size S00 allows for compact installation in enclosures with limited space.

Compatibility and Accessories
The device is part of the SIRIUS system building kit and can be combined with various accessories. These include auxiliary switches, which can be mounted laterally or horizontally, as well as undervoltage release units for different voltage ranges. Auxiliary switches are available in various configurations, e.g. with 1NO + 1NC or 1 changeover contact, and are used for signal transmission or controlling other components. Connection modules and busbars for multiple power switches enable structured and efficient wiring. Accessories are uniformly available for all sizes of the SIRIUS system.

Mounting and Installation
The switch is mounted using screw connections, with conductors directly secured to the terminal clamps. Installation takes place in an enclosure or distribution board, complying with the electrical and mechanical requirements of the respective standards (e.g. IEC). Wiring can be simplified by using the SIRIUS 3RV29 feed-in system, which reduces main circuit wiring. Mounting is typically done in vertical or horizontal orientation, depending on the enclosure configuration.

Advantages in Operation
The motor protection circuit breaker offers high reliability through the combination of thermal and magnetic tripping. Low heat dissipation reduces thermal stress in the enclosure and improves component lifespan. Global approvals enable use in various countries and industries. The modular design of the SIRIUS system allows flexible expansion and adaptation to specific requirements. The integrated protection function enhances system safety and prevents damage from overload or short circuit.

Protection Rating
The weather-resistant design and approval for hazardous areas (ATEX/IEC Ex) indicate a robust construction that meets requirements in demanding operating environments. Use in IT networks is also possible, provided electrical and mechanical requirements of the respective standards are observed.