General
Degree of protectionIP20
Operating voltage690 V
A-trigger0,45...0,63 A
N-trigger8,2 A
Protection classClass 10
Auxiliary switch1S+1Ö
Connection typeScrew connection
Short-circuit breaking capacity (Icu)100 kA
Operation temperature-20...+60 °C
Power consumption5 W
Connection cross-section (main current circuit)0,5...2,5 mm²
Connection cross-section (auxiliary switch)0,5...2,5 mm²
Mounting methodScrew and click mounting on 35 mm rail
Application rangeMotor protection, hazardous areas (ATEX/IEC Ex), IT networks
The Siemens motor protection circuit breaker type 3RV1011-0GA15 belongs to size S00 of the SIRIUS series and is specifically designed for use in motor protection. It provides safe disconnection in the event of short circuit and protects consumers and systems against overload. Additionally, it enables safe isolation of the system from the power supply. The circuit breaker is optimized for use in consumer branch circuits, particularly for motors of efficiency class IE3 and IE4, and features low heat dissipation, making it suitable for densely populated control panels. Size S00 allows compact mounting on a 35 mm standard mounting rail in accordance with DIN EN 50022, with mounting possible in any position.

Applications
The motor protection circuit breaker is intended for use in industrial systems, particularly in drive technology. It is used in control panels where reliable protection against overload and short circuit is required. Global certification according to IEC and UL/CSA, as well as suitability for hazardous areas (ATEX or IEC Ex), expands its application range across various industries. It is also available for use in IT networks, provided the specific requirements for the control panel are considered.

Functions and Equipment in Detail
The circuit breaker features a thermomagnetic tripping unit that responds to both overload (A-trip) and short circuit (N-trip). The A-trip is adjustable in the range of 0.45 to 0.63 A, while the N-trip is 8.2 A. The protection class is Class 10, ensuring rapid disconnection in the event of a short circuit. An integrated transverse auxiliary switch with 1S+1Oe (1 changeover, 1 normally open) is standard and enables signaling functions in the control circuit. The auxiliary switch contacts are rated for operating voltages up to 24 V and 230 V AC, as well as 24 V and 60 V DC, with operating currents ranging from 0.15 A to 2 A depending on voltage.

Technology Explained Simply
The circuit breaker operates with screw terminals for the main current circuit and has a maximum operating voltage of 690 V AC. The switching capacity is designed for AC-3 operation, with a rated current of 0.63 A at 400 V AC. The maximum short-circuit breaking capacity (Icu) is 100 kA at 240 V, 400 V, 500 V, and 690 V AC. The mechanical life of the main contacts is typically 100,000 switching cycles. The protection rating IP20 on the front side protects against finger contact and ingress of solid foreign objects. The operating ambient temperature ranges from -20 °C to +60 °C, while storage and transport temperature can reach up to +80 °C. The maximum installation height is 2000 m above sea level. The total power consumption is typically 5 W.

Compatibility and Accessories
The circuit breaker is part of the SIRIUS system building kit and can be combined with various accessories that are uniformly available for all sizes. These include auxiliary switches such as 3RV2901-1C, 3RV2901-1J, 3RV2901-1B, 3RV2901-1A, 3RV2901-1E, as well as undervoltage release units such as 3RV2902-1AM1, 3RV2902-1AB0, 3RV2902-1AF0, 3RV2902-1AB4, 3RV2902-1AP0, 3RV2902-1AV1. Additional components include connection modules (e.g. 3RA1911-1AA00), 3-phase busbars (e.g. 3RV1915-1BB, 3RV1915-1AB), and feed-in terminals (e.g. 3RV2925-5AB, 3RV2915-5B). Using the SIRIUS 3RV29 feed-in system significantly reduces main circuit wiring.

Mounting and Installation
The circuit breaker is mounted using screw and click mounting on a 35 mm standard mounting rail in accordance with DIN EN 50022. Dimensions are 90 mm height, 45 mm width, and 81 mm depth. Mounting is possible in any position. The connection cross-sections for the main circuit range from 0.5 to 2.5 mm² for single- and multi-core cables, including fine-stranded cable with core end processing. The connection cross-sections for the auxiliary switch also range from 0.5 to 2.5 mm². Electrical connections are made via screw terminals.

Operational Advantages
The circuit breaker offers high reliability through its thermomagnetic tripping function and integrated auxiliary switch function. Low heat dissipation reduces thermal load in the control panel. Global certification and suitability for hazardous areas expand application possibilities. Compatibility with the SIRIUS system building kit enables flexible and modular system design. The IP20 protection rating ensures safe operation in indoor environments. The mechanical life of 100,000 switching cycles ensures long service life.