Further information for Siemens 3RV1011-0GA10 motor protection switch S00 0,45–0,63 A
General
Degree of protection
IP20
Operating voltage
690 V
Release class
10
Construction size
S00
A-trigger
0,45...0,63 A
N-trigger
8,2 A
Power loss
5 W
Operation temperature
-20...+60 °C
Connection cross-section solid
0,5...1,5 mm²
Connection cross-section stranded
0,75...2,5 mm²
Connection cross-section fine-stranded
0,5...1,5 mm²
Connection cross-section AWG
18...14
Switching capacity
Standard
Short-circuit current (Icu)
100 kA
Operating frequency
15 1/h
Rated current at 400 V
0,63 A
Operating power at 400 V
0,18 kW
Screw terminal
Thermal-magnetic trip unit
SIRIUS system building block
The Siemens motor protection circuit breaker type 3RV1011-0GA10 belongs to size S00 of the SIRIUS series and is specifically designed for motor protection. It provides safe disconnection in the event of a short circuit and protects consumers and systems from overload. Additionally, it enables safe isolation of the system from the power supply. The device is optimized for use in consumer branch circuits, particularly for IE3/IE4 motors, and features low heat generation. Its compact design and weather-resistant construction make it suitable for industrial applications. Worldwide approvals such as IEC and UL/CSA, as well as suitability for hazardous areas (ATEX or IEC Ex), are standard.
Applications
The motor protection circuit breaker is intended for use in industrial systems, particularly in drive technology and for controlling electric motors. It is suitable for applications in IT networks as well as for main or emergency stop switches. Size S00 allows for compact installation, for example in enclosures or distribution boards. The protection functions include short-circuit and overload protection, with the thermal tripping function responsible for overload protection and the magnetic tripping function for short-circuit protection.
Functions and Equipment in Detail
The switch features a thermal-magnetic tripping unit that responds to both overload and short-circuit conditions. The adjustment ranges are 0.45 to 0.63 A for the thermal tripping unit (A-trip) and 8.2 A for the magnetic tripping unit (N-trip). The tripping class is 10, meaning the switch disconnects within 10 seconds in the event of a short circuit if the current exceeds 10 times the rated current. The operating voltage is up to 690 V, with the switch having a rated current of 0.63 A at 400 V. The operating frequency is limited to a maximum of 15 switching operations per hour. The switch is equipped with screw terminals, with the main current circuits connected via screw terminals. The connection cross-sections for solid, stranded, and fine-stranded conductors are 0.5 to 1.5 mm² and 0.75 to 2.5 mm² respectively. The connection type is arranged on the front of the device for the main current circuit.
Technology Explained Simply
The switch operates on the principle of a thermal-magnetic tripping unit. The thermal component responds to sustained overloads by tripping the switch due to the heat generated by a bimetal strip. The magnetic component reacts immediately to high current surges, such as those occurring during short circuits, and disconnects within milliseconds. Tripping class 10 defines the maximum time within which the switch disconnects during a short circuit. The protection rating IP20 on the front protects against finger contact and ingress of solid foreign objects. The maximum operating temperature is +60 °C, while the storage and transport temperature ranges from -50 °C to +80 °C. The mechanical life expectancy is typically 100,000 switching cycles. The power loss is typically 5 W, explaining the low heat generation. The surge voltage withstand is 6,000 V, demonstrating robustness against transient voltage spikes.
Compatibility and Accessories
The switch is part of the SIRIUS system building kit and can be combined with various accessories that are standardized across all sizes. Compatible accessories include auxiliary switches, undervoltage release units, and connection modules. For example, auxiliary switches such as the 3RV2901-1E (horizontal, 1S + 1OE) or the 3RV2901-1B (side-mountable) are available. Undervoltage release units like the 3RV2902-1AB4 or 3RV2902-1AB0 can be used for additional safety. The use of supply systems such as SIRIUS 3RV29 reduces wiring in the main current circuit. Mounting is done on a 35 mm standard rail according to DIN EN 50022, with mounting position being arbitrary.
Mounting and Installation
The switch is mounted using screw and clamp connections onto a 35 mm standard rail. Mounting can be done in any position, with dimensions of 90 mm (height), 45 mm (width), and 81 mm (depth). The required clearances for side and rear mounting are 0 mm each. The connection terminals are located on the front of the device, with the main current circuits connected via screw terminals. The connection cross-sections are defined for different conductor types (solid, stranded, fine-stranded). Installation is carried out in enclosures or distribution boards, with the ambient temperature ranging from -20 °C to +60 °C. The maximum installation height is 2,000 m above sea level.
Advantages in Operation
The switch offers high reliability through its thermal-magnetic tripping function and tripping class 10. The low power loss of 5 W ensures minimal heat generation, facilitating integration into densely packed enclosures. Worldwide approvals and suitability for hazardous areas expand the range of applications. The standardized accessory range within the SIRIUS series allows for flexible expansion and maintenance. Mounting on standard rails and the compact design simplify installation and replacement. The IP20 protection rating ensures safe operation and protection against foreign objects.
Protection Rating
The IP20 protection rating on the front protects against finger contact and ingress of solid foreign objects. The device is not intended for outdoor use or in damp environments, as no water tightness (IP67 or higher) is provided.
Operating Voltage
The operating voltage is up to 690 V, with the switch having a rated current of 0.63 A at 400 V. The voltage is designed for alternating current (AC).
Tripping Class
The tripping class is 10, meaning the switch disconnects within 10 seconds in the event of a short circuit if the current exceeds 10 times the rated current.
Screw Connection
The switch features screw connections for the main current circuits, with defined connection cross-sections for solid, stranded, and fine-stranded conductors.
Size
Size S00 enables compact installation, particularly in enclosures and distribution boards.
Thermal-Magnetic Tripping Unit
The tripping unit combines thermal and magnetic functions to detect and disconnect both overload and short-circuit conditions.
SIRIUS System Building Kit