| General |
| Switch type | Auxiliary switch block |
| Connection type | Screw connection |
| Number of normally open contacts | 2 |
| Contact designation | .3/.4, .3/.4 |
| Current busbar | 1 S, 1 S |
| Mounting position | Front-mounted |
| Compatibility | For contactors 3RT2 and auxiliary contactors 3RH2 |
| Switching behavior | Instantaneous switching |
| Contact type | Positive-guided contact elements |
| System series | SIRIUS |
The Siemens auxiliary switch block 3RH2911-1HA20 is a front-mounted component from the SIRIUS series, specifically designed to extend auxiliary contacts in the control circuit of power contactors from series 3RT2 and auxiliary contactors from series 3RH2. It serves as an additional contact carrier to expand control functions in industrial systems without requiring additional switching devices or complex modifications. The size is independent of the respective contactor size, allowing the auxiliary switch to be flexibly mounted on various devices.
Applications
The auxiliary switch block is used in industrial control systems where additional switching contacts are required for signals, status monitoring, or logic control. It is particularly suitable for applications in manufacturing automation, machine building, and plant control, where the reliability and fast response of control contacts are critical. Front-side mounting enables a compact and clear installation, minimizing space requirements in the enclosure.
Functions and Equipment in Detail
The auxiliary switch 3RH2911-1HA20 features two closing contacts (2 S), each marked with contact designations .3/.4. These contacts switch without delay, meaning they operate in direct synchrony with the main contact of the contactor or auxiliary contactor. The contacts are designed as mechanically linked elements, ensuring a mechanical connection to the main contact and thus providing a secure and reliable switching function. The current path is equipped with one closing contact per contact (1 S, 1 S), ensuring electrical conductivity in the control circuit.
Technology Explained Simply
The screw connection type enables a secure and durable connection for the wiring. Front-side mounting is tool-free, simplifying installation and maintenance. Size independence means the auxiliary switch can be mounted on various contactor sizes, as long as the front plate is compatible.
Compatibility and Accessories
The auxiliary switch is specifically designed for use with power contactors from series 3RT2 and auxiliary contactors from series 3RH2. It can be used as a mirror contact with power contactors or as a mechanically linked contact in auxiliary contactors. As an accessory, the auxiliary switch block 3RH29112HA20 is available, which also features two closing contacts (2S) with spring-loaded connection. This can be used as an alternative or supplement to the screw connection, depending on the requirements at the connection point.
Mounting and Installation
Mounting is done front-side directly onto the contactor or auxiliary contactor, requiring no tools. The mechanical connection is achieved via a clamp or plug connection, ensuring secure fastening. The connection terminals are designed for screw connection, enabling connection to cables or wires. Installation is quick and requires no additional components.
Advantages in Operation
Using the auxiliary switch block 3RH2911-1HA20 allows flexible expansion of control functions without changing the existing contactor configuration. The mechanically linked switching ensures high reliability, as the auxiliary contacts always switch in synchrony with the main contact. Front-side mounting and tool-free installation reduce mounting time and simplify maintenance. Compatibility with various contactor sizes increases flexibility in use.