General
ManufacturerSiemens
Product typeBase plate
Insertfor YD starters
Compatibility2x 3RT1.5 (size S6), 1x 3RT2.4 (size S3)
SystemSIRIUS system building block
The Siemens base plate 3RA1952-2E is a component of the SIRIUS system kit, specifically designed for mounting a combination of three contactors for use in star-delta starting circuits. It serves as the mechanical base for integrating two contactors of size S6 (type 3RT1.5) and one contactor of size S3 (type 3RT2.4). This configuration enables secure and structured mounting of components in industrial control systems, particularly in installations requiring a YD starter (star-delta start). The base plate is part of a modular system that supports flexible and efficient arrangement of contactors in enclosures.

Applications

The base plate is used in industrial installations where a star-delta start is required to limit the inrush current of electric motors. This is common with large motors to avoid network loading and to increase the service life of the installation. Mounting takes place in enclosures, where the base plate provides the spatial and mechanical foundation for the three contactors. Use within the SIRIUS system ensures standardized and compatible integration with other system components.

Functions and Equipment in Detail

The base plate 3RA1952-2E is designed for mounting two contactors of size S6 and one contactor of size S3. Size S6 corresponds to contactors 3RT1.5, while size S3 corresponds to contactors 3RT2.4. The construction allows for stable and secure fastening of the contactors, with positioning already predetermined for the typical arrangement in a YD starter. The base plate is part of a modular system that enables easy expansion and maintenance of the control equipment.

Technology Explained Simply

The base plate is a mechanical component that does not perform any electrical functions, but exclusively enables the physical mounting of contactors. The contactors themselves handle the electrical control of the start: initially, the motor is connected via star connection to limit the inrush current. After reaching nominal speed, the motor is switched to delta connection to achieve full power. The base plate ensures that the three contactors are mounted in the correct spatial arrangement to allow these switching operations to proceed safely and reliably.

Compatibility and Accessories

The base plate is specifically designed for the combination of two contactors 3RT1.5 (size S6) and one contactor 3RT2.4 (size S3). These contactors are part of the SIRIUS system and can be combined with other components of this system. The base plate is not intended for other contactor configurations. Use within the SIRIUS system ensures high compatibility with other system components, such as auxiliary contactors, contacts, or switching devices.

Mounting and Installation

Mounting takes place in an enclosure, where the base plate is fastened at the designated location. The contactors are then mounted onto the base plate, with positioning already predetermined for the star-delta start circuit. Fastening is done via the designated mounting points on the base plate. Installation requires no additional tools or components, as the base plate exclusively enables the mechanical mounting of contactors.

Advantages in Operation

Using the base plate 3RA1952-2E provides structured and secure mounting of contactors in a YD starter. The modular construction of the SIRIUS system enables easy maintenance and expansion of the installation. The predetermined arrangement of contactors reduces mounting errors and ensures a uniform and clear circuit layout. Compatibility with other SIRIUS components ensures high flexibility in system design.

Protection Rating

The base plate itself is not an electrical device and does not have a protection rating in the sense of IP classification. The protection rating of the entire control assembly is determined by the installed contactors and the enclosure construction. However, the base plate is designed for use in industrial environments and meets the mechanical requirements for mounting in enclosures.

System Integration

The base plate is part of the SIRIUS system by Siemens, which is based on modular components. This enables flexible and scalable system design. Integration into existing enclosures occurs without additional modifications, as the base plate uses standard dimensions and mounting points of the SIRIUS system. Use of SIRIUS components ensures high compatibility and reliability in industrial applications.