Further information for Siemens 3NJ4915-2GA11 cam switch for 3NJ41
General
Primary current
250 A
Secondary current
1 A
Accuracy class
0,5
Compatibility
3NJ41 fuse disconnecting bars size NH1-3
Accessory for
SENTRON protective switching devices
Calibration
The article 3NJ4915-2GA11 from Siemens is an integrable current transformer, specifically developed for use with fuse switch disconnectors of the 3NJ41 series in sizes NH1 to NH3. It serves as an accessory component for SENTRON protective switching devices and enables the measurement of current values in industrial operation. The current transformer is designed for a nominal current of 250 amperes and delivers a secondary current of 1 ampere, making it suitable for use in measurement and protection systems standardized on these values. The accuracy class 0.5 ensures high measurement accuracy, which is required for applications in energy distribution and monitoring. The transformer is calibrated, ensuring the reliability of measurement values in official applications.
Applications
The current transformer 3NJ4915-2GA11 is used in industrial electrical installations, particularly in switchgear, where accurate current measurement is necessary for monitoring, control, or protection functions. It is specifically designed for integration into fuse switch disconnectors of the 3NJ41 series, which are used in medium-voltage installations and distribution systems in sizes NH1 to NH3. Use in SENTRON protective switching devices enables direct connection to protection and control systems that respond to the transformer’s signals.
Functions and Equipment in Detail
The current transformer is designed as an integrable module that is directly installed into the designated rails of the 3NJ41 series. It is rated for a nominal load of 250/1 A, with the primary current being 250 A and the secondary current 1 A. The accuracy class 0.5 means that the deviation of the measured value from the actual value is at most 0.5 %, which is sufficient for precise applications in energy monitoring. The calibration of the transformer ensures that the measurement values comply with legal requirements and may be used in official contexts.
Technology Explained Simply
A current transformer such as the 3NJ4915-2GA11 transforms a high primary current (here 250 A) into a low, measurable secondary current (here 1 A), which can be connected to measuring instruments, protection relays, or controls. The accuracy class 0.5 describes the maximum allowable deviation of the measurement, ensuring data reliability. Calibration is carried out according to legal regulations to confirm the correctness of the measurement values. Integration into the 3NJ41 rails enables compact and secure mounting without additional fastening elements.
Compatibility and Accessories
The current transformer is exclusively intended for fuse switch disconnectors of the 3NJ41 series in sizes NH1 to NH3. It is part of the SENTRON system from Siemens and is used in protective switching devices of this series. Compatibility is limited to these specific rail types; use in other systems is not intended.
Mounting and Installation
Mounting is achieved by direct integration into the designated rails of the 3NJ41 series. No additional fastening elements are required, as the transformer is mechanically hung or inserted into the rail. Electrical connection is made via the designated connection points of the rail. Installation is carried out as part of the overall switchgear assembly and requires no special tools or additional effort.
Advantages in Operation
Integration of the current transformer into the rail reduces space requirements and simplifies installation. The high accuracy of class 0.5 and calibration ensure reliable measurement values, which are critical for controlling and monitoring electrical installations. Use in SENTRON protective switching devices enables direct connection to protection and control systems, increasing system integrity. The reliability of the transformer contributes to the safety and efficiency of the entire installation.