| Complementary |
| Power consumption in W | 2.0 W |
| Power consumption in VA | 5.5 VA |
| Input voltage | 690 V |
| Input detection threshold | 50 mV; 65 mV; 85 mV; 110 mV; 140 mV; 180 mV; 230 mV; 300 mV; 400 mV; 500 mV |
| Time delay | 0.5 s; 1 s; 2 s; 3 s; 5 s; 8 s; 12 s; 20 s; 35 s; 60 s |
| [Ie] rated operational current | 5 A AC-1 for normally open relay contact; 3 A AC-15 for normally open relay contact; 5 A DC-1 for normally open relay contact; 3 A DC-13 for normally open relay contact |
| [Ith] conventional free air thermal current | 6 A for NO relay output circuit |
| Associated fuse rating | 6 A gG for relay output conforming to IEC 60947-1 |
| Standards | IEC 60947-5-1; IEC 61508-1 functional safety standard; IEC 61508-2 functional safety standard; IEC 61508-3 functional safety standard; IEC 61508-4 functional safety standard; IEC 61508-5 functional safety standard; IEC 61508-6 functional safety standard; IEC 61508-7 functional safety standard; ISO 13849-1 functional safety standard; IEC 62061 functional safety standard |
| Minimum output current | 10 mA for relay output |
| Minimum output voltage | 5 V for relay output |
| [Ui] rated insulation voltage | 690 V phase to phase (pollution degree 2) conforming to IEC 60947-1; 400 V phase to earth (pollution degree 2) conforming to IEC 60947-1 |
| [Uimp] rated impulse withstand voltage | 4 kV overvoltage category II conforming to IEC 60947-1 |
| Local signalling | LED green with power marking for power ON; LED red with error marking for error; LED yellow with state marking for status; LED yellow with L12 marking for input line comparison; LED yellow with L32 marking for input line comparison |
| Connections - terminals | Removable screw terminal block solid or flexible cable: 0.2...2.5 mm²; Removable screw terminal block flexible with ferrule cable: 0.25...2.5 mm² single conductor; Removable screw terminal block solid or flexible cable: 0.2...1.5 mm² twin conductor; Removable screw terminal block flexible with ferrule cable: 2 x 0.25...1 mm² without cable end, with bezel; Removable screw terminal block flexible with ferrule cable: 2 x 0.5...1.5 mm² with cable end, with bezel |
| Mounting support | 35 mm symmetrical DIN rail |
| Depth | 120 mm |
| Height | 100 mm |
| Width | 22.5 mm |
| Net weight | 0.2 kg |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| IP degree of protection | IP20 (terminals) conforming to IEC 60529; IP40 (housing) conforming to IEC 60529; IP54 (mounting area) conforming to IEC 60529 |
| Ambient air temperature for operation | -25…55 °C |
| Ambient air temperature for storage | -40…70 °C |
| Relative humidity | 5…95 % non-condensing |
| Logistical informations |
| Country of origin | ID |
| Main |
| Range of product | Harmony Safety Automation |
| Product or component type | Safety module |
| Safety module name | XPSUVN |
| Safety module application | For zero speed detection |
| Function of module | Monitoring 3-phase motor; Monitoring 3-phase motor with star-delta starting; Monitoring 3-phase motor with variable number of poles; Monitoring 3-phase motor with variable number of poles and star-delta starting; Monitoring dc motor; Monitoring servo motor; Monitoring 3-phase motor supplied by variable speed drive; Monitoring 3-phase motor supplied by servo drive; Controlling enegization to open of guard switch type XCSE, XCSLE, XCSLF, XCST |
| Safety level | Can reach PL e/category 3 for normally open relay contact conforming to ISO 13849-1; Can reach SILCL 3 for normally open relay contact conforming to IEC 62061; Can reach SIL 3 for normally open relay contact conforming to IEC 61508 |
| Safety reliability data | MTTFd > 30 years conforming to ISO 13849-1; Dcavg = 98.9 % conforming to ISO 13849-1; PFHd = 2.39E-9 1/h conforming to ISO 13849-1; HFT = 1 conforming to IEC 62061; PFHd = 2.39E-9 1/h conforming to IEC 62061; SFF > 99% conforming to IEC 62061; HFT = 1 conforming to IEC 61508-1; PFHd = 2.39E-9 1/h conforming to IEC 61508-1; SFF > 99% conforming to IEC 61508-1; Type = B conforming to IEC 61508-1 |
| Product certifications | TÜV; cULus |
| [Us] rated supply voltage | 24 V AC - 15...10 %; 24 V DC - 20...20 % |
| Output type | Relay, 1 NO circuit(s), volt-free |
| Number of additional circuits | 2 solid state outputs |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 6.900 cm |
| Package 1 Width | 13.500 cm |
| Package 1 Length | 15.700 cm |
| Package 1 Weight | 263.000 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 16 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 4.857 kg |
The Harmony XPS Universal safety relays are characterized by their range of functions and diagnostic capabilities, which reduce downtime in the event of a fault. This safety relay includes safe standstill detection by measuring the remanent voltage, so that no further sensors need to be installed. To do this, the motor cable is connected to the standstill monitor and the voltage induced by the expiring rotary movement is measured after the motor is switched off. If the measured remanent voltage falls below the limit value set on the front (50-500 mV), the motor is assumed to be at a standstill. In addition, a delay time of 0.5 to 60 seconds can also be set on the front. DC and AC motors in 1- or 3-phase networks up to 690 V can be monitored for motor standstill. This safety switching device has 1 safe relay normally open contact, 1 semiconductor signaling output and 1 diagnostic message as an output. With the help of the qualified diagnostics, states and errors are detected and transmitted to a standard input of a PLC using a telegram via direct wiring. A ready-made function block for common control systems evaluates these messages so that the operator is fully informed on the machine display. The supply voltage is 24 VAC and 24 VDC and the connections are made via removable screw terminals. Applications up to safety level PL e in category 3 or SIL3 can be realized. If the number of outputs is to be increased, the XPSUEP extension can simply be connected to the side via an integrated connector and cross-wiring can be dispensed with, saving time. It is mounted by snapping it onto a top hat rail or screwing it onto mounting plates. A uniquely numbered locking strap is included to protect the settings under the transparent cover. A wide range of approvals enable international use. Thanks to the Green Premium environmental label, you can receive detailed information on material content, environmental impact and circular economy that supports your sustainability goals.