| Complementary |
| Synchronisation time between inputs | 0.5 s; 2 s; 2.2 s; 4 s |
| Type of start | Automatic/manual/monitored |
| Power consumption in W | 4.5 W 24 V DC |
| Power consumption in VA | 10.5 VA 24 V AC 50/60 Hz |
| Input protection type | Internal, electronic |
| safety outputs | 3 NO + 1 NC |
| safety inputs | 6 safety input 24 V DC 5 mA |
| maximum wire resistance | 500 Ohm |
| Input compatibility | Normally closed circuit conforming to ISO 14119; XC limit switch conforming to ISO 14119; Mechanical contact conforming to ISO 14119; Normally closed circuit conforming to ISO 13850; Antivalent pair conforming to ISO 14119; OSSD pair conforming to IEC 61496-1-2; 3-wire proximity sensors PNP |
| [Ie] rated operational current | 5 A AC-1 for normally open relay contact; 3 A AC-15 for normally open relay contact; 5 A DC-1 for normally open relay contact; 3 A DC-13 for normally open relay contact; 3 A AC-1 for normally closed relay contact; 1 A AC-15 for normally closed relay contact; 3 A DC-1 for normally closed relay contact; 1 A DC-13 for normally closed relay contact |
| control outputs | 7 on/off configurable pulsed output |
| Input/output type | Semiconductor pulsed diagnostic output 24 V DC, 20 mA Z1, not safety-related |
| [Ith] conventional free air thermal current | 16 A |
| Associated fuse rating | 10 A gG for NO relay output circuit conforming to IEC 60947-1; 4 A gG for NC relay output circuit conforming to IEC 60947-1 |
| Minimum output current | 10 mA for relay output |
| Minimum output voltage | 12 V for relay output |
| Maximum response time on input open | 20 ms |
| [Ui] rated insulation voltage | 250 V (pollution degree 2) conforming to IEC 60947-1 |
| [Uimp] rated impulse withstand voltage | 4 kV overvoltage category II conforming to IEC 60947-1 |
| Mounting support | 35 mm symmetrical DIN rail |
| Depth | 120 mm |
| Height | 100 mm |
| Width | 45 mm |
| Net weight | 0.350 kg |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | IEC 60947-5-1; IEC 61508-1 functional safety standard; IEC 61508-2 functional safety standard; IEC 61508-3 functional safety standard; IEC 61508-4 functional safety standard; IEC 61508-5 functional safety standard; IEC 61508-6 functional safety standard; IEC 61508-7 functional safety standard; ISO 13849-1 functional safety standard; IEC 62061 functional safety standard |
| Product certifications | TÜV; cULus |
| IP degree of protection | IP20 (terminals) conforming to IEC 60947-1; IP40 (housing) conforming to IEC 60947-1; IP54 (mounting area) conforming to IEC 60947-1 |
| Ambient air temperature for operation | -25…50 °C at 24 V AC; -25…55 °C at 24 V DC |
| Ambient air temperature for storage | -25…85 °C |
| Relative humidity | 5…95 % non-condensing |
| Logistical informations |
| Country of origin | ID |
| Main |
| Range of product | Harmony Safety Automation |
| Product or component type | Safety module |
| Safety module name | XPSUDN |
| Safety module application | Monitoring antivalent contacts; For emergency stop, guard and light curtain monitoring |
| Function of module | Emergency stop button with 2 NC contacts; Guard monitoring with 1 or 2 limit switches; Monitoring 2 PNP sensors; Magnetic switch monitoring; Light curtain monitoring; RFID switch; Monitoring of electro-sensitive protection equipment (ESPE); Proximity sensor monitoring |
| Safety level | Can reach PL e/category 4 for normally open relay contact conforming to ISO 13849-1; Can reach SILCL 3 for normally open relay contact conforming to IEC 62061; Can reach SIL 3 for normally open relay contact conforming to IEC 61508; Can reach PL c/category 1 for normally closed relay contact conforming to ISO 13849-1; Can reach SILCL 1 for normally closed relay contact conforming to IEC 62061; Can reach SIL 1 for normally closed relay contact conforming to IEC 61508 |
| Safety reliability data | MTTFd > 30 years conforming to ISO 13849-1; Dcavg >= 99 % conforming to ISO 13849-1; PFHd = 0.88E-09 conforming to ISO 13849-1; HFT = 1 conforming to IEC 62061; PFHd = 0.88E-09 conforming to IEC 62061; SFF > 99% conforming to IEC 62061; HFT = 1 conforming to IEC 61508-1; PFHd = 0.88E-09 conforming to IEC 61508-1; SFF > 99% conforming to IEC 61508-1; Type = B conforming to IEC 61508-1 |
| Electrical circuit type | NC pair; PNP pair; Antivalent pair; OSSD pair |
| Connections - terminals | Removable screw terminal block, 0.2...2.5 mm² solid or flexible; Removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor; Removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor; Removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel; Removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel |
| [Us] rated supply voltage | 24 V AC - 15...10 %; 24 V DC - 20...20 % |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 6.500 cm |
| Package 1 Width | 15.500 cm |
| Package 1 Length | 13.500 cm |
| Package 1 Weight | 416.000 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 16 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 7.217 kg |
The Harmony XPS Universal safety relays are ideal for use in a variety of safety applications thanks to their selectable safety function and start option using rotary switches on the front. This reduces the number of variants of the devices required and the diagnostic function allows states to be easily transferred to a PLC, so that in the event of a fault, downtimes are reduced by clear error information. The required function can be easily set from 8 selectable safety functions. Mechanical contacts from emergency stop/stop buttons, position or magnetic switches, as well as electronic PNP sensors, light curtains or RFID safety switches with OSSD outputs can be connected to the inputs. A safety function can be operated via the 12 inputs in 6x two-channel (redundant) versions. Automatic, manual or monitored start as well as an optional start-up test are available for the start function. This safety switching device has 3 safe relay normally open contacts, 1 normally closed contact and 1 diagnostic message as outputs. With the help of qualified diagnostics, states and errors are detected and transmitted to a standard input of a PLC using a telegram via direct wiring. A ready-made function block for common control systems evaluates these messages so that the operator is comprehensively informed on the machine display. The supply voltage is 24 VAC/DC and the connections are made via removable screw terminals. Applications up to safety level PL e in category 4 or SIL3 can be realized. If the number of outputs is to be increased, the XPSUEP extension can simply be connected to the side via an integrated connector and cross-wiring can be dispensed with, saving time. Installation is carried out by snapping it onto a top hat rail or screwing it onto mounting plates. A uniquely numbered locking strap is included to protect the settings under the transparent cover. A wide range of approvals enable international use. Thanks to the Green Premium environmental label, you can receive detailed information on material content, environmental impact and circular economy that supports your sustainability goals.