Schneider Electric XPSUAT33A3AC, EAN: 3606489601706

Schneider Electric XPSUAT33A3AC safety relay 10FKT 1K 3+3S

Schneider Electric XPSUAT33A3AC safety relay 10FKT 1K 3+3S

Lieske Part No. 1861727
Mfg Part No XPSUAT33A3AC
EAN-Code 3606489601706
Manufacturer Schneider Electric
Here only 395,20 EUR
470,29 EUR incl. VAT

Further information for Schneider Electric XPSUAT33A3AC safety relay 10FKT 1K 3+3S

Complementary
Synchronisation time between inputs0.5 s; 2 s; 4 s
Type of startAutomatic/manual/monitored
Power consumption in W4 W 48 V DC
Power consumption in VA10 VA 240 V AC 50/60 Hz
Input protection typeInternal, electronic
safety outputs1 NC configurable; 3 NO configurable; 3 NO immediate
safety inputs2 positive safety input 24 V DC 8 mA; 1 negative safety input
maximum wire resistance500 Ohm
Time delay range0...900 s off delay
Input compatibilityNormally closed circuit conforming to ISO 14119; XC limit switch conforming to ISO 14119; Mechanical contact conforming to ISO 14119; Normally closed circuit conforming to ISO 13850; Antivalent pair conforming to ISO 14119; OSSD pair conforming to IEC 61496-1-2; 3-wire proximity sensors PNP
[Ie] rated operational current5 A AC-1 for normally open relay contact; 3 A AC-15 for normally open relay contact; 5 A DC-1 for normally open relay contact; 3 A DC-13 for normally open relay contact; 3 A AC-1 for normally closed relay contact; 1 A AC-15 for normally closed relay contact; 3 A DC-1 for normally closed relay contact; 1 A DC-13 for normally closed relay contact
control outputs4 on/off configurable pulsed output
Input/output typePulsed output for diagnostics 24 V DC, 20 mA Z1, not safety-related; Semiconductor output 24 V DC, 20 mA Z2, not safety-related
[Ith] conventional free air thermal current16 A
Associated fuse rating10 A gG for NO relay output circuit conforming to IEC 60947-1
Minimum output current20 mA for relay output
Minimum output voltage24 V for relay output
Maximum response time on input open20 ms
[Ui] rated insulation voltage250 V (pollution degree 2) conforming to IEC 60947-1
[Uimp] rated impulse withstand voltage4 kV overvoltage category II conforming to IEC 60947-1
Mounting support35 mm symmetrical DIN rail
Depth120 mm
Height100 mm
Width45 mm
Net weight0.350 kg
Contractual warranty
Warranty (in months)18
Environment
StandardsIEC 60947-5-1; IEC 61508-1 functional safety standard; IEC 61508-2 functional safety standard; IEC 61508-3 functional safety standard; IEC 61508-4 functional safety standard; IEC 61508-5 functional safety standard; IEC 61508-6 functional safety standard; IEC 61508-7 functional safety standard; ISO 13849-1 functional safety standard; IEC 62061 functional safety standard
Product certificationsTÜV; cULus
IP degree of protectionIP54 (mounting area) conforming to IEC 60947-1; IP40 (housing) conforming to IEC 60947-1; IP20 (terminals) conforming to IEC 60947-1
Ambient air temperature for storage-25…85 °C
Relative humidity5…95 % non-condensing
Logistical informations
Country of originID
Main
Range of productHarmony Safety Automation
Product or component typeSafety module
Safety module nameXPSUAT
Safety module applicationMonitoring antivalent contacts; For emergency stop, guard and light curtain monitoring; Monitoring of pressure-sensitive 4-wire protective devices
Function of moduleEmergency stop button with 2 NC contacts; Guard monitoring with 1 or 2 limit switches; Monitoring 2 PNP sensors; Magnetic switch monitoring; Light curtain monitoring; RFID switch; Monitoring of electro-sensitive protection equipment (ESPE); Sensing mat/edges; Proximity sensor monitoring; Monitoring 1 PNP + 1 NPN sensor
Safety levelCan reach PL e/category 4 for normally open relay contact conforming to ISO 13849-1; Can reach SILCL 3 for normally open relay contact conforming to IEC 62061; Can reach SIL 3 for normally open relay contact conforming to IEC 61508; Can reach PL c/category 1 for normally closed relay contact conforming to ISO 13849-1; Can reach SILCL 1 for normally closed relay contact conforming to IEC 62061; Can reach SIL 1 for normally closed relay contact conforming to IEC 61508
Electrical circuit typeNC pair; PNP pair; Antivalent pair; OSSD pair
Connections - terminalsRemovable spring terminal block, 0.2...2.5 mm² solid or flexible; Removable spring terminal block, 0.25...2.5 mm² flexible with ferrule single conductor; Removable spring terminal block, 0.2...1.5 mm² solid or flexible twin conductor; Removable spring terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel; Removable spring terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel
[Us] rated supply voltage48...240 V AC/DC - 10...10 %
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height6.800 cm
Package 1 Width14.000 cm
Package 1 Length15.800 cm
Package 1 Weight460.000 g
Unit Type of Package 2S03
Number of Units in Package 216
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight8.170 kg
The Harmony XPS Universal safety relays are ideal for use in a variety of safety applications thanks to their selectable safety function and start option using rotary switches on the front. This reduces the number of variants of the devices required and the diagnostic function allows states to be easily transferred to a PLC, so that in the event of a fault, downtimes are reduced by clear error information. The required function can be easily set from 10 selectable safety functions. Mechanical contacts from emergency stop/stop buttons, position or magnetic switches, safety mats as well as electronic PNP/NPN sensors, light curtains or RFID safety switches with OSSD outputs can be connected to the inputs. A safety function can be operated via the two inputs in a two-channel (redundant) version. Automatic, manual or monitored start as well as an optional start-up test are available for the start function. This safety switching device has 3 safe, undelayed relay contacts as output and optionally 3 safe, delayed contacts, 1 break contact and 1 semiconductor signal output, as well as 1 diagnostic message. The switch-off delayed time functions (e.g. stop category 1 or 2, SS1 or SS2) can be set in steps from 0.1 second to 15 minutes. With the help of the qualified diagnostics, states and errors are detected and transmitted to a standard input of a PLC using a telegram via direct wiring. A ready-made function block for common control systems evaluates these messages so that the operator is comprehensively informed on the machine display. The supply voltage is 48-240 VAC/DC and the connections are made via removable spring-loaded terminals. Applications up to safety level PL e in category 4 or SIL3 can be realized. If the number of outputs needs to be increased, the XPSUEP extension can simply be connected to the side via an integrated connector, saving time by eliminating cross-wiring. Installation is done by snapping it onto a top hat rail or screwing it onto mounting plates. A uniquely numbered locking strap is included to protect the settings under the transparent cover. A wide range of approvals enable international use. Thanks to the Green Premium eco-label, you can obtain detailed information on material content, environmental impact and circular economy that supports your sustainability goals.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1861727
qrcode für Schneider Electric XPSUAT33A3AC safety relay 10FKT 1K 3+3S