| Complementary |
| Synchronisation time between inputs | 0.5 s; 2.2 s |
| Type of start | Automatic/manual/monitored |
| Power consumption in W | 2.0 W 48 V DC |
| Power consumption in VA | 6.5 VA 240 V AC 50/60 Hz |
| Input protection type | Internal, electronic |
| safety outputs | 1 C/O |
| safety inputs | 1 safety input 24 V DC 5 mA |
| maximum wire resistance | 500 Ohm |
| Input compatibility | Normally closed circuit conforming to ISO 14119; XC limit switch conforming to ISO 14119; Mechanical contact conforming to ISO 14119; Normally closed circuit conforming to ISO 13850; Antivalent pair conforming to ISO 14119; OSSD pair conforming to IEC 61496-1-2; Two-hand control conforming to EN 574/ISO 13851-III A; 3-wire proximity sensors PNP |
| [Ie] rated operational current | 5 A AC-1 for normally open relay contact; 3 A AC-15 for normally open relay contact; 5 A DC-1 for normally open relay contact; 3 A DC-13 for normally open relay contact; 3 A AC-1 for normally closed relay contact; 1 A AC-15 for normally closed relay contact; 2 A DC-1 for normally closed relay contact; 1 A DC-13 for normally closed relay contact |
| Control Outputs | 2 on/off configurable pulsed output |
| Input/output type | Semiconductor pulsed diagnostic output 24 V DC, 20 mA Z1, not safety-related |
| [Ith] conventional free air thermal current | 3 A |
| Associated fuse rating | 6 A gG for relay output conforming to IEC 60947-1 |
| Minimum output current | 10 mA for relay output |
| Minimum output voltage | 15 V for relay output |
| Maximum response time on input open | 20 ms |
| [Ui] rated insulation voltage | 250 V (pollution degree 2) conforming to IEC 60947-1 |
| [Uimp] rated impulse withstand voltage | 4 kV overvoltage category II conforming to IEC 60947-1 |
| Local signalling | LED (green) for power ON; LED (red) for error; LED (yellow) for start; LED (yellow) for safety status; LED (yellow) for safety input S12; LED (yellow) for safety input S13 |
| Mounting support | 35 mm symmetrical DIN rail |
| Depth | 120 mm |
| Ambient air temperature for operation | -25…55 °C |
| Height | 100 mm |
| Width | 22.5 mm |
| Net weight | 0.200 kg |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | IEC 60947-5-1; IEC 61508-1 functional safety standard; IEC 61508-2 functional safety standard; IEC 61508-3 functional safety standard; IEC 61508-4 functional safety standard; IEC 61508-5 functional safety standard; IEC 61508-6 functional safety standard; IEC 61508-7 functional safety standard; ISO 13849-1 functional safety standard; IEC 62061 functional safety standard |
| Product certifications | TÜV; cULus |
| IP degree of protection | IP20 (terminals) conforming to IEC 60529; IP40 (housing) conforming to IEC 60529; IP54 (mounting area) conforming to IEC 60529 |
| Relative humidity | 5…95 % non-condensing |
| Logistical informations |
| Country of origin | ID |
| Main |
| Range of product | Harmony Safety Automation |
| Product or component type | Safety module |
| Safety module name | XPSUAB |
| Safety module application | For electrical monitoring of two-hand control stations; For application with safety switchover contact; For emergency stop, guard and light curtain monitoring; Monitoring antivalent contacts |
| Function of module | Emergency stop monitoring 1-channel wiring; Guard monitoring 1-channel wiring; Monitoring 1 PNP sensor; Monitoring two-hand control station type IIIA; Magnetic switch monitoring; Light curtain monitoring; RFID switch; Monitoring of electro-sensitive protection equipment (ESPE); Proximity sensor monitoring |
| Safety level | Can reach PL = c conforming to ISO 13849-1; Can reach SILCL 1 conforming to IEC 62061; Can reach SIL 1 conforming to IEC 61508 |
| Safety reliability data | MTTFd >= 30 years conforming to ISO 13849-1; Dcavg < 60 % conforming to ISO 13849-1; PFHd = 1177E-09 1/h conforming to ISO 13849-1; HFT = 0 conforming to IEC 62061; PFHd = 1177E-09 1/h conforming to IEC 62061; SFF > 60% conforming to IEC 62061; HFT=0 conforming to IEC 61508-1; PFHd = 1177E-09 1/h conforming to IEC 61508-1; SFF > 60% conforming to IEC 61508-1; Type = B conforming to IEC 61508-1 |
| Electrical circuit type | NC pair; PNP pair; Antivalent pair; OSSD pair |
| Connections - terminals | Removable screw terminal block, 0.2...2.5 mm² solid or flexible; Removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor; Removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor; Removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel; Removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel |
| [Us] rated supply voltage | 48...240 V AC/DC - 10...10 % |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 6.5 cm |
| Package 1 Width | 13.5 cm |
| Package 1 Length | 15.5 cm |
| Package 1 Weight | 262.0 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 16 |
| Package 2 Height | 30 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 4.939 kg |
The Harmony XPS Universal safety relays are ideal for use in a variety of safety applications thanks to their selectable safety function and start option using rotary switches on the front. This reduces the number of variants of the devices required and the diagnostic function allows states to be easily transferred to a PLC, so that in the event of a fault, downtime is reduced by clear error information. The required function can be easily set from 6 selectable safety functions. Mechanical contacts from emergency stop/stop buttons, position switches, magnetic switches, two-hand operation type IIIA, electronic PNP sensors, light curtains or RFID safety switches with OSSD outputs can be connected to the inputs. Automatic, manual or monitored start as well as an optional start-up test are available for the start function. This safety switching device has 1 safe relay changeover contact and 1 diagnostic message as an output. With the help of the qualified diagnostics, states and errors are detected and transferred to a standard input of a PLC using a telegram via direct wiring. A ready-made function block for common control systems evaluates these messages so that the operator is fully informed on the machine display. The supply voltage is 48-240 VAC/DC and the connections are made via removable screw terminals. Applications up to safety level PL c in category 1 or SIL1 can be realized. Installation is done by snapping onto a top hat rail or screwing onto mounting plates. A uniquely numbered locking strap is included to protect the settings under the transparent cover. A wide range of approvals enable international use. Thanks to the Green Premium environmental label, you can receive detailed information on material content, environmental impact and circular economy that supports your sustainability goals.