| Complementary |
| Power consumption in W | 3 W |
| Power dissipation in W | 3 W |
| Integrated connection type | Backplane expansion bus |
| Number of terminal blocks | 6 |
| Connections - terminals | 2 captive screw clamp terminals, removable terminal block; 1 captive screw clamp terminals, removable terminal block |
| Safety level | Can reach category 4 conforming to ISO 13849-1; Can reach PL = e conforming to ISO 13849-1; Can reach SIL 3 conforming to IEC 61508; SILCL 3 conforming to IEC 62061 |
| Quality labels | CE |
| Discrete input voltage | 24 V DC |
| Local signalling | 1 LED green with PWR marking for power ON; 1 LED green with RUN marking for RUN (status); 1 LED red with E IN marking for internal error; 1 LED red with E EX marking for external error; 2 LEDs orange with ADDR marking for node address; 16 LEDs yellow with IN marking for input status |
| Mounting support | Omega 35 mm DIN rail conforming to EN 50022 |
| Depth | 22.5 mm |
| Height | 99 mm |
| Width | 114.5 mm |
| Net weight | 0.25 kg |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | IEC 61800-5-1; IEC 61508; ISO 13849-1; IEC 62061 |
| Product certifications | RCM; TÜV; cULus |
| IP degree of protection | IP20 (enclosure) |
| Ambient air temperature for operation | -10…55 °C |
| Ambient air temperature for storage | -20…85 °C |
| Relative humidity | 10…95 % |
| Pollution degree | 2 |
| [Uimp] rated impulse withstand voltage | 4 kV conforming to IEC 61800-5-1 |
| Safety reliability data | DC > 99 %; MTTFd < 100 years high; PFHd = 7.09E-9 1/h |
| Insulation | 250 V AC between power supply and housing conforming to IEC 61800-5-1 |
| Overvoltage category | II |
| Electromagnetic compatibility | Electrostatic discharge immunity test - test level: 6 kV (on contact) conforming to IEC 61000-4-2; Electrostatic discharge immunity test - test level: 20 kV (on air) conforming to IEC 61000-4-2; Susceptibility to electromagnetic fields - test level: 10 V/m (80...1000 MHz) conforming to IEC 61000-4-3; Susceptibility to electromagnetic fields - test level: 30 V/m (1.4 GHz...2 GHz) conforming to IEC 61000-4-3 |
| Vibration resistance | +/-0.35 mm (f= 10…55 Hz) conforming to IEC 61496-1 |
| Shock resistance | 10 gn (duration = 16 ms) for 1000 shocks on each axis conforming to IEC 61496-1 |
| service life | 20 year(s) |
| Logistical informations |
| Country of origin | IT |
| Main |
| Range of product | Preventa Safety automation |
| Product or component type | Safe input expansion module |
| Device short name | XPSMCM |
| Electrical connection | Screw terminal |
| [Us] rated supply voltage | 24 V - 20...20 % DC |
| Input type | 16 digital |
| Output type | 4 test for line control |
| Discrete input type | Isolated |
| Discrete output type | PNP |
| Function of module | Monitoring safety detection for discrete input; Monitoring safety dialogue for discrete input |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 4.400 cm |
| Package 1 Width | 12.800 cm |
| Package 1 Length | 16.400 cm |
| Package 1 Weight | 241.000 g |
| Unit Type of Package 2 | S01 |
| Number of Units in Package 2 | 6 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 15.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 1.700 kg |
Mit dem Modicon modularer Sicherheitscontroller XPSMCM lassen sich Sicherheitsanwendungen einfach konfigurieren und das System mit Modulen entsprechend der Anwendung flexibel erweitern. Dieses Erweiterungsmodul verfügt über 16 sicheren digitalen Eingängen. Zur Querschlusserkennung der Sicherheitskreise stehen 4 getakte Kontrollausgänge zur Verfügung. Zur Anbindung an den internen Bus liegt der benötigte Rückwand-Busstecker der Verpackung bei. Das Modul verfügt über abziehbare Schraubklemmen. Dieses Erweiterungsmodul ist mit allen CPU-Versionen verwendbar. Zur Unterstützung Ihrer Nachhaltigkeitsziele werden detaillierte Informationen zu Materialinhalten, Umweltauswirkungen und Kreislaufwirtschaft bereitgestellt.